Computer-aided detection in diagnostic mammography: detection of clinically unsuspected cancers.

Sherry A Butler1, Richard J Gabbay, Deborah A Kass, Daniel E Siedler, Kathryn F O'shaughnessy, Ronald A Castellino.   

Abstract

OBJECTIVE: We had two objectives: to determine the percentage of women presenting with clinical findings whose diagnostic mammogram led to detection of a breast cancer at a site distant from the original clinical complaint and to assess the performance of computer-aided detection (CAD) on diagnostic mammography.
MATERIALS AND METHODS: Three institutions contributed consecutive cases in which a mammogram was obtained to evaluate a clinical finding, after which a histologic diagnosis of breast cancer was made. Clinical data and the mammograms were reviewed to determine the nature of the clinical findings and to document the location and characteristics of 212 biopsy-proven cancers in 197 patients who met the study criteria. Standard four-view breast mammograms were then analyzed by a CAD system.
RESULTS: The most common clinical finding was a palpable mass (90%, 177/197), with nipple discharge (5%, 9/197), focal tenderness or pain (2%, 5/197), and miscellaneous complaints (3%, 6/197) also noted. Two separate cancers were found in 7.6% (15/197) of the cases. In another 7.6% (15/197) of the cases, the single diagnosed cancer was not at the location of the specific clinical finding. The CAD system correctly marked 87% (26/30) of those cancers that were clinically unsuspected (i.e., not at the location of the clinical finding).
CONCLUSION: Breast cancers occurred at locations other than the site of the presenting clinical finding in 15% (30/197) of patients undergoing diagnostic mammography in whom a cancer was detected. CAD identified 87% of these incidentally detected cancers and may therefore be useful as a detection aid to the radiologist when interpreting diagnostic mammograms.

Entities:  

Mesh:

Year:  2004        PMID: 15505329     DOI: 10.2214/ajr.183.5.1831511

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  4 in total

Review 1.  CAD for mammography: the technique, results, current role and further developments.

Authors:  Ansgar Malich; Dorothee R Fischer; Joachim Böttcher
Journal:  Eur Radiol       Date:  2006-01-17       Impact factor: 5.315

Review 2.  Computer-aided diagnosis in medical imaging: historical review, current status and future potential.

Authors:  Kunio Doi
Journal:  Comput Med Imaging Graph       Date:  2007-03-08       Impact factor: 4.790

Review 3.  Advances in computer-aided diagnosis for breast cancer.

Authors:  Lubomir Hadjiiski; Berkman Sahiner; Heang-Ping Chan
Journal:  Curr Opin Obstet Gynecol       Date:  2006-02       Impact factor: 1.927

Review 4.  An engineering view on megatrends in radiology: digitization to quantitative tools of medicine.

Authors:  Namkug Kim; Jaesoon Choi; Jaeyoun Yi; Seungwook Choi; Seyoun Park; Yongjun Chang; Joon Beom Seo
Journal:  Korean J Radiol       Date:  2013-02-22       Impact factor: 3.500

  4 in total