Literature DB >> 15498907

The clinical value of 3-dimensional saline infusion sonography in addition to 2-dimensional saline infusion sonography in women with abnormal uterine bleeding: work in progress.

Cornelis D de Kroon1, Leonie A Louwé, J Baptist Trimbos, Frank Willem Jansen.   

Abstract

OBJECTIVE: To evaluate the clinical relevance of 3-dimensional saline infusion sonography (3D-SIS) in addition to conventional SIS in women with abnormal uterine bleeding suspected of having intrauterine abnormalities.
METHODS: All women suspected of having intrauterine abnormalities were eligible. Before 3D-SIS, conventional SIS was performed. The results of these techniques were compared with the "combined method reference standard" (hysteroscopy, endometrial sampling, and clinical follow-up in cases with normal SIS findings). Diagnostic characteristics (with 95% confidence intervals [CIs]) of 3D-SIS and SIS were calculated as well as their respective accuracy in evaluating the histologic nature, the intrauterine extension, and the location of intrauterine abnormalities. Moreover, the reliability (kappa value) and clinical relevance of 3D-SIS were assessed.
RESULTS: A total of 49 women were included, and 4 women were excluded. The positive predictive values of 3D-SIS and SIS were, respectively, 1.00 and 0.86 (95% CI, 0.72-0.99; P = .15), and the diagnostic accuracy values were 0.98 (95% CI, 0.94-1.0) and 0.91 (95% CI, 0.83-0.99; P = .08). Saline infusion sonography and 3D-SIS were equally accurate in evaluating the histologic nature, intrauterine extent, and location of intrauterine abnormalities (respective kappa values: 0.85 versus 0.93; P = .88; 0.83 versus 0.83; and 0.77 versus 0.80; P = .81). The reliability of 3D-SIS was good: intraobserver and interobserver agreement (kappa) were 0.78 and 0.72. Three women (6.7%) had the benefit of additional 3D-SIS: in these women, SIS wrongly led to a diagnosis of intrauterine abnormalities (P = .08).
CONCLUSIONS: Three-dimensional saline infusion sonography is valid and reliable in women suspected of having intrauterine abnormalities and may indeed have relevant clinical value in addition to conventional SIS.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15498907     DOI: 10.7863/jum.2004.23.11.1433

Source DB:  PubMed          Journal:  J Ultrasound Med        ISSN: 0278-4297            Impact factor:   2.153


  5 in total

Review 1.  The impact of uterine leiomyomas on reproductive outcomes.

Authors:  H Cook; M Ezzati; J H Segars; K McCarthy
Journal:  Minerva Ginecol       Date:  2010-06

Review 2.  Three-dimensional saline infusion sonography compared to two-dimensional saline infusion sonography for the diagnosis of focal intracavitary lesions.

Authors:  Lotte L Nieuwenhuis; Frederik Jr Hermans; A J Marjolein Bij de Vaate; Mariska Mg Leeflang; Hans Am Brölmann; Wouter Jk Hehenkamp; Ben Willem J Mol; T Justin Clark; Judith Af Huirne
Journal:  Cochrane Database Syst Rev       Date:  2017-05-05

Review 3.  Management of uterine fibroids in the patient pursuing assisted reproductive technologies.

Authors:  Mohammad Ezzati; John M Norian; James H Segars
Journal:  Womens Health (Lond)       Date:  2009-07

Review 4.  Premenopausal abnormal uterine bleeding and risk of endometrial cancer.

Authors:  M E Pennant; R Mehta; P Moody; G Hackett; A Prentice; S J Sharp; R Lakshman
Journal:  BJOG       Date:  2016-10-20       Impact factor: 6.531

Review 5.  Diagnostic value of three-dimensional saline infusion sonohysterography in the evaluation of the uterus and uterine cavity lesions.

Authors:  Ahmed S A Sabry; Shimaa A Fadl; Wojciech Szmigielski; Amal Alobaidely; Sanaa S H Ahmed; Hanan Sherif; Reda R H Yousef; Ahmed Mahfouz
Journal:  Pol J Radiol       Date:  2018-11-30
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.