Cardiac surgery often is associated with a significant disruption of the coagulation system, particularly in high risk patients such as those undergoing placement of ventricular assist devices. This type of severe coagulopathy can lead to life threatening bleeding that can require massive transfusions to restore hemostasis. Recently, recombinant activated factor VII (rFVlla) has been +used as an alternative to massive transfusion for the treatment of refractory bleeding in several patient populations, including cardiac surgery patients. In the case reported here, the patient's risk was compounded by multiple operations in a short period of time and circulatory collapse that was initially managed with a shortterm left ventricular assist device. After multiple failed attempts at weaning the patient from circulatory assistance, he was taken back to the operating room for conversion to a chronic, implantable device. This procedure was complicated by a severe coagulopathy secondary to a myriad of factors commonly encountered after the use of cardiopulmonary bypass. The administration of rFVlla resulted in a rapid cessation of bleeding without thrombotic complications. This is the first case reported involving an acute to chronic bridge patient. Despite the anecdotal success of rFVlla, further clinical research is needed to establish both the safety and economic feasibility of this agent.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15497395     DOI: 10.1097/01.mat.0000136516.16726.35

Source DB:  PubMed          Journal:  ASAIO J        ISSN: 1058-2916            Impact factor:   2.872


  2 in total

1.  Use of activated recombinant factor VII for severe coagulopathy post ventricular assist device or orthotopic heart transplant.

Authors:  Manish J Gandhi; Richard A Pierce; Lini Zhang; Marc R Moon; George J Despotis; Nader Moazami
Journal:  J Cardiothorac Surg       Date:  2007-07-06       Impact factor: 1.637

Review 2.  Recombinant activated factor VII (Novo7) in patients with ventricular assist devices: case report and review of the current literature.

Authors:  Daniel Heise; Anselm Bräuer; Michael Quintel
Journal:  J Cardiothorac Surg       Date:  2007-10-26       Impact factor: 1.637

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.