Literature DB >> 15496735

The partial Talbot effect and its use in measuring the coherence of synchrotron X-rays.

Jean-Pierre Guigay1, Simon Zabler, Peter Cloetens, Christian David, Rajmund Mokso, Michel Schlenker.   

Abstract

The Talbot effect is the self-imaging, at distances D multiple of D(R), of the intensity downstream of a periodic object. Earlier work with hard synchrotron radiation X-rays showed the variation with D of the fundamental Fourier component of intensity to be a good measurement of beam coherence. Any higher-order Fourier coefficients I (D, m > 1) would be periodic with a reduced period D(Rm) = D(R)/m for an ideally coherent incident beam (partial Talbot effect). The degree of coherence gamma(x) is sampled through the ratio of I (D, m) at D = 0 and multiples of D(Rm). This requires the Fourier coefficient for D = 0, which is not accessible for a phase object (no contrast at D = 0). However, the ratio of the slopes of I (D, m) at D = 0 and D = pD(Rm) also provides this information. Furthermore, a characterization of gamma(x) is possible, provided an assumption is made on its shape, using only the ratio of the Fourier coefficient I (D, m) of two images a distance pD(Rm) apart. Experiments with one- and two-dimensional phase gratings and a mixed (amplitude and phase) two-dimensional grating confirm that the partial Talbot effect approach is viable. It requires a reduced range of distances, and yields important results directly, obviating the need for computer fits. In particular, 8% of the beam intensity was found to have very low coherence in the vertical direction, probably due to monochromator imperfection.

Entities:  

Mesh:

Year:  2004        PMID: 15496735     DOI: 10.1107/S0909049504024811

Source DB:  PubMed          Journal:  J Synchrotron Radiat        ISSN: 0909-0495            Impact factor:   2.616


  3 in total

1.  Measurement of X-ray Beam Coherence along Multiple Directions Using 2-D Checkerboard Phase Grating.

Authors:  Shashidhara Marathe; Xianbo Shi; Michael J Wojcik; Albert T Macrander; Lahsen Assoufid
Journal:  J Vis Exp       Date:  2016-10-11       Impact factor: 1.355

2.  Probing transverse coherence of x-ray beam with 2-D phase grating interferometer.

Authors:  Shashidhara Marathe; Xianbo Shi; Michael J Wojcik; Naresh G Kujala; Ralu Divan; Derrick C Mancini; Albert T Macrander; Lahsen Assoufid
Journal:  Opt Express       Date:  2014-06-16       Impact factor: 3.894

3.  A high visibility Talbot-Lau neutron grating interferometer to investigate stress-induced magnetic degradation in electrical steel.

Authors:  Tobias Neuwirth; Alexander Backs; Alex Gustschin; Simon Vogt; Franz Pfeiffer; Peter Böni; Michael Schulz
Journal:  Sci Rep       Date:  2020-02-04       Impact factor: 4.379

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.