Literature DB >> 15495170

Anatomical study of perforator arteries in the distally based radial forearm fasciosubcutaneous flap.

Cesare Tiengo1, Veronica Macchi, Andrea Porzionato, Francesco Bassetto, Franco Mazzoleni, Raffaele De Caro.   

Abstract

We investigated the anatomical vascular basis of the forearm fasciosubcutaneous flap (FSC-F), fed by the distal perforator arteries of the fascia. This type of flap was proposed, in hand reconstructive surgery, to avoid the disadvantages caused by axial-pattern reverse radial forearm fasciocutaneous flap, based on ligation and rotation of the radial artery (RA). In eight fresh cadaveric forearms, the RA was injected slowly with acrylic resin and the superficial flexor compartment was dissected. Then the FSC-F was raised from the lateral margins of the sample to the median RA axis, and the collaterals of the RA (number, interval of origin, and caliber) were evaluated. The fascial branches of RA (mean number +/- SD: 20 +/- 3) originated mainly from the radial and ulnar sides of the RA. In the distal forearm the vessels were more numerous (mean value = 11.3 vs. 8.9; Student's t-test, P < 0.05) but smaller in diameter (mean value = 0.45 mm vs. 0.63 mm; Student's t-test, P < 0.05). The perforator arteries forked in a T-shape following the main axis of the forearm and anastomosed in the fascial plane, forming longitudinal fan-shaped arterial chains giving rise to the vascular epifascial network. Histological (hematoxylin-eosin, azan-Mallory, Weigert) and immunohistochemical (anti-von Willebrand factor) study of the FSC-F at different levels of sampling was also carried out. The epifascial branches of distal sections were smaller in diameter (78.3 +/- 35.5 microm) than those of intermediate (105.7 +/- 28.7 microm; Newman-Keuls test, P < 0.01) and proximal (116.8 +/- 31.2 microm; Newman-Keuls test, P < 0.001) sections. Our findings indicate that the perforator arteries and epifascial branches are smaller in the distal forearm, so that during surgical dissection, the safety distance from the radial styloid should take into account that also in the presence of a sufficient number of vessels in the distal forearm their caliber could be inadequate to the hemodynamic request of the flap. Thus, rather than on a theoretic distance from the radial styloid, the length of the flap should be based on an accurate evaluation of the individual vascularization of the forearm case by case.

Entities:  

Mesh:

Year:  2004        PMID: 15495170     DOI: 10.1002/ca.20009

Source DB:  PubMed          Journal:  Clin Anat        ISSN: 0897-3806            Impact factor:   2.414


  4 in total

1.  The proximal radial artery perforator flap (PRAP-flap): an anatomical study for its use in elbow reconstruction.

Authors:  Cesare Tiengo; Veronica Macchi; Andrea Porzionato; Carla Stecco; Anna Parenti; Franco Bassetto; Raffaele De Caro
Journal:  Surg Radiol Anat       Date:  2007-03-29       Impact factor: 1.246

Review 2.  Forensic Implications of Anatomical Education and Surgical Training With Cadavers.

Authors:  Carmelo Pirri; Carla Stecco; Andrea Porzionato; Rafael Boscolo-Berto; René H Fortelny; Veronica Macchi; Marko Konschake; Stefano Merigliano; Raffaele De Caro
Journal:  Front Surg       Date:  2021-06-23

3.  Assisted Salvage of Ischemic Fasciocutaneous Flap Using Adipose-Derived Mesenchymal Stem Cells: In-Situ Revascularization.

Authors:  Michael H Carstens; Mauricio Mendieta; Cecilia Pérez; Esperanza Villareal; Rodolfo Garcia
Journal:  Aesthet Surg J       Date:  2017-07-01       Impact factor: 4.283

4.  Vascular Analysis of Radial Artery Perforator Flaps.

Authors:  Ehtaih Sham; Jaumie Ayala Masia; Thyagraj Jayaram Reddy
Journal:  Ann Maxillofac Surg       Date:  2018 Jan-Jun
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.