Literature DB >> 15494135

A glucose biosensor based on chitosan-glucose oxidase-gold nanoparticles biocomposite formed by one-step electrodeposition.

Xi-Liang Luo1, Jing-Juan Xu, Ying Du, Hong-Yuan Chen.   

Abstract

An amperometric biosensor for the quantitative measurement of glucose is reported. The biosensor is based on a biocomposite that is homogeneous and easily prepared. This biocomposite is made of chitosan hydrogel, glucose oxidase, and gold nanoparticles by a direct and facile electrochemical deposition method under enzyme-friendly conditions. The resulting biocomposite provided a shelter for the enzyme to retain its bioactivity at considerably extreme conditions, and the decorated gold nanoparticles in the biocomposite offer excellent affinity to enzyme. The biosensor exhibited a rapid response (within 7s) and a linear calibration range from 5.0 microM to 2.4 mM with a detection limit of 2.7 microM for the detection of glucose. The combination of gold nanoparticles affinity and the promising feature of the biocomposite with the onestep nonmanual technique favor the sensitive determination of glucose with improved analytical capabilities.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15494135     DOI: 10.1016/j.ab.2004.07.005

Source DB:  PubMed          Journal:  Anal Biochem        ISSN: 0003-2697            Impact factor:   3.365


  14 in total

Review 1.  Gold nanoparticles in chemical and biological sensing.

Authors:  Krishnendu Saha; Sarit S Agasti; Chaekyu Kim; Xiaoning Li; Vincent M Rotello
Journal:  Chem Rev       Date:  2012-02-02       Impact factor: 60.622

Review 2.  Electrodes modified with 3D graphene composites: a review on methods for preparation, properties and sensing applications.

Authors:  Nadeem Baig; Tawfik A Saleh
Journal:  Mikrochim Acta       Date:  2018-05-07       Impact factor: 5.833

3.  Evaluation of luminol chemiluminescence based on simultaneous introducing of coumarin derivatives as green fluorophores and chitosan-induced Au/Ag alloy nanoparticle as catalyst for the sensitive determination of glucose.

Authors:  M J Chaichi; S O Alijanpour; S Asghari; S Shadlou
Journal:  J Fluoresc       Date:  2015-02-03       Impact factor: 2.217

4.  Ultra-Sensitive Nano Optical Sensor Samarium-Doxycycline Doped in Sol Gel Matrix for Assessment of Glucose Oxidase Activity in Diabetics Disease.

Authors:  Marwa M Tharwat; M S Attia; M S Alghamdi; Amr M Mahros
Journal:  J Fluoresc       Date:  2017-07-11       Impact factor: 2.217

5.  Versatile potentiometric metabolite sensing without dioxygen interference.

Authors:  Nicole L Walker; Jeffrey E Dick
Journal:  Biosens Bioelectron       Date:  2021-12-15       Impact factor: 10.618

6.  Fusing Sensor Paradigms to Acquire Chemical Information: An Integrative Role for Smart Biopolymeric Hydrogels.

Authors:  Eunkyoung Kim; Yi Liu; Hadar Ben-Yoav; Thomas E Winkler; Kun Yan; Xiaowen Shi; Jana Shen; Deanna L Kelly; Reza Ghodssi; William E Bentley; Gregory F Payne
Journal:  Adv Healthc Mater       Date:  2016-09-12       Impact factor: 9.933

7.  Oxidase-loaded hydrogels for versatile potentiometric metabolite sensing.

Authors:  Nicole L Walker; Jeffrey E Dick
Journal:  Biosens Bioelectron       Date:  2021-01-17       Impact factor: 10.618

8.  A Third Generation Glucose Biosensor Based on Cellobiose Dehydrogenase Immobilized on a Glassy Carbon Electrode Decorated with Electrodeposited Gold Nanoparticles: Characterization and Application in Human Saliva.

Authors:  Paolo Bollella; Lo Gorton; Roland Ludwig; Riccarda Antiochia
Journal:  Sensors (Basel)       Date:  2017-08-18       Impact factor: 3.576

Review 9.  Functionalized Gold Nanoparticles and Their Biomedical Applications.

Authors:  Pooja M Tiwari; Komal Vig; Vida A Dennis; Shree R Singh
Journal:  Nanomaterials (Basel)       Date:  2011-06-14       Impact factor: 5.076

Review 10.  Fully integrated biochip platforms for advanced healthcare.

Authors:  Sandro Carrara; Sara Ghoreishizadeh; Jacopo Olivo; Irene Taurino; Camilla Baj-Rossi; Andrea Cavallini; Maaike Op de Beeck; Catherine Dehollain; Wayne Burleson; Francis Gabriel Moussy; Anthony Guiseppi-Elie; Giovanni De Micheli
Journal:  Sensors (Basel)       Date:  2012-08-08       Impact factor: 3.576

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.