Literature DB >> 15492898

A novel implantation technique for closure of an atypical fenestration connecting the right atrial appendage to an extracardiac conduit by use of a 15 mm Helex device in a patient with total cavopulmonary connection.

M Peuster1, P Beerbaum.   

Abstract

We report on a 7-years old patient after total cavopulmonary anastomosis with an extracardiac conduit. An atypical fenestration was created during the operation connecting the right atrial appendage to the extracardiac conduit. Because of arterial desaturation, the fenestration connecting the anterior wall of the extracardiac conduit to the posterior wall of the right atrial appendage was successfully occluded with a 15 mm Helex device by use of a modified implantation technique.

Entities:  

Mesh:

Year:  2004        PMID: 15492898     DOI: 10.1007/s00392-004-0127-8

Source DB:  PubMed          Journal:  Z Kardiol        ISSN: 0300-5860


  23 in total

1.  Is it necessary to routinely fenestrate an extracardiac fontan?

Authors:  L D Thompson; E Petrossian; D B McElhinney; N A Abrikosova; P Moore; V M Reddy; F L Hanley
Journal:  J Am Coll Cardiol       Date:  1999-08       Impact factor: 24.094

Review 2.  The Fontan procedure: analysis of cohorts and late complications.

Authors:  R M Freedom; R Hamilton; S J Yoo; H Mikailian; L Benson; B McCrindle; H Justino; W G Williams
Journal:  Cardiol Young       Date:  2000-10       Impact factor: 1.093

3.  Fenestrated Fontan operation with delayed transcatheter closure of atrial septal defect. Improved results in high-risk patients.

Authors:  G S Kopf; C S Kleinman; Z M Hijazi; J T Fahey; M L Dewar; W E Hellenbrand
Journal:  J Thorac Cardiovasc Surg       Date:  1992-06       Impact factor: 5.209

4.  Fontan fenestration closure in the catheterization laboratory--echocardiographic evaluation of residual right to left shunts.

Authors:  C Gomez; T Lloyd; R Mosca; E Bove; A Ludomirsky
Journal:  Am J Cardiol       Date:  1998-11-15       Impact factor: 2.778

5.  Baffle fenestration with subsequent transcatheter closure. Modification of the Fontan operation for patients at increased risk.

Authors:  N D Bridges; J E Lock; A R Castaneda
Journal:  Circulation       Date:  1990-11       Impact factor: 29.690

6.  Outcome after the single-stage, nonfenestrated Fontan procedure.

Authors:  D T Hsu; J M Quaegebeur; F F Ing; E J Selber; J M Lamour; W M Gersony
Journal:  Circulation       Date:  1997-11-04       Impact factor: 29.690

7.  Transcatheter coil occlusion of surgical fenestration after Fontan operation.

Authors:  R J Sommer; M Recto; R J Golinko; R B Griepp
Journal:  Circulation       Date:  1996-08-01       Impact factor: 29.690

8.  Transcatheter closure of fontan fenestrations using the Amplatzer septal occluder: initial experience and follow-up.

Authors:  C G Cowley; S Badran; D Gaffney; A P Rocchini; T R Lloyd
Journal:  Catheter Cardiovasc Interv       Date:  2000-11       Impact factor: 2.692

9.  Improved early morbidity and mortality after Fontan operation: the Mayo Clinic experience, 1987 to 1992.

Authors:  F Cetta; R H Feldt; P W O'Leary; D D Mair; C A Warnes; D J Driscoll; D J Hagler; C J Porter; K P Offord; H V Schaff; F J Puga; G K Danielson
Journal:  J Am Coll Cardiol       Date:  1996-08       Impact factor: 24.094

10.  Total cavopulmonary connection with an extracardiac conduit: experience with 100 patients.

Authors:  Shigehiko Tokunaga; Hideaki Kado; Yutaka Imoto; Munetaka Masuda; Yuichi Shiokawa; Kouji Fukae; Naoki Fusazaki; Shiro Ishikawa; Hisataka Yasui
Journal:  Ann Thorac Surg       Date:  2002-01       Impact factor: 4.330

View more
  1 in total

1.  Recanalisation of bilateral superior vena cava after total cavopulmonary connection. Interventional occlusion with the Amplatzer VSD Occluder.

Authors:  M Girisch; L Sieverding; R Rauch; R Kaulitz; M Gass; G Ziemer; M Hofbeck
Journal:  Z Kardiol       Date:  2005-07
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.