Literature DB >> 15491480

Measurement of refractive error and accommodation with the photorefractor PowerRef II.

Stephanie Jainta1, Wolfgang Jaschinski, Jörg Hoormann.   

Abstract

The infrared photorefractor PowerRef II (PR II; PlusoptiX AG, Nurnberg, Germany) uses the principle of eccentric photorefraction. In eight subjects the mean non-cycloplegic refraction measured with the 'Full Scan' mode of the PR II at a far viewing distance (0.2 D) was significantly more hypermetropic by 0.6 D compared with subjective refraction. The mean accommodation differed by about this same amount between the PR II and the Canon R1 at three different viewing distances (3, 2 and 1 D). The PR II refraction at the 1 m reference distance was 0.25 D more hypermetropic compared with the subjective refraction at far (5 m); these measures were moderately correlated (r = 0.7). To determine temporal changes, the 'Dynamic Scan' mode was used over a 2-min period: the mean intraindividual standard deviation was 0.32 mm for pupil diameter and 0.29 D for accommodation, while the absolute measurement error of the 'Dynamic Scan' was found to be <0.12 D for the accommodation data. Interindividual reliabilities were satisfactory. However, the PR II did not provide a continuous stream of data and the specified sampling frequency of 25 Hz was rarely realized.

Mesh:

Year:  2004        PMID: 15491480     DOI: 10.1111/j.1475-1313.2004.00233.x

Source DB:  PubMed          Journal:  Ophthalmic Physiol Opt        ISSN: 0275-5408            Impact factor:   3.117


  6 in total

1.  An objective technique to measure the depth-of-focus in free space.

Authors:  Balamurali Vasudevan; Kenneth J Ciuffreda; Bin Wang
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2005-12-15       Impact factor: 3.117

2.  Suitability of open-field autorefractors as pupillometers and instrument design effects.

Authors:  Carles Otero; Mikel Aldaba; Oriol Ferrer; Andrea Gascón; Juan C Ondategui-Parra; Jaume Pujol
Journal:  Int J Ophthalmol       Date:  2017-04-18       Impact factor: 1.779

3.  Dynamic distance direct ophthalmoscopy, a novel technique to assess accommodation in children.

Authors:  Mihir Kothari; Suvarna Balankhe; Shalaka Paralkar; Deepali Nar; Shreya Bhagat; Shashank Ranade
Journal:  Indian J Ophthalmol       Date:  2012 Mar-Apr       Impact factor: 1.848

Review 4.  Advantages, limitations, and diagnostic accuracy of photoscreeners in early detection of amblyopia: a review.

Authors:  Irene Sanchez; Sara Ortiz-Toquero; Raul Martin; Victoria de Juan
Journal:  Clin Ophthalmol       Date:  2016-07-22

5.  Ocular accommodation and cognitive demand: an additional indicator besides pupil size and cardiovascular measures?

Authors:  Stephanie Jainta; Joerg Hoormann; Wolfgang Jaschinski
Journal:  J Negat Results Biomed       Date:  2008-08-23

6.  Dose-dependent naloxone-induced morphine withdrawal symptoms in opioid-dependent males-a double-blinded, randomized study.

Authors:  Stefan Weisshaar; Laura Brandt; Brigitte Litschauer; Safoura Sheik-Rezaei; Laura Moser; Günther Nirnberger; Elisabeth Kühberger; Ulrike Bauer; Christa Firbas; Ghazaleh Gouya; Michael Wolzt; Gabriele Fischer
Journal:  Br J Clin Pharmacol       Date:  2020-03-20       Impact factor: 4.335

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.