Literature DB >> 15490036

Most patients with abdominal aortic aneurysm are not suitable for endovascular repair using currently approved bifurcated stent-grafts.

Stephane Elkouri1, Eugenio Martelli, Peter Gloviczki, Michael A McKusick, Jean M Panneton, James C Andrews, Audra A Noel, Thomas C Bower, Timothy M Sullivan, Charles Rowland, Tanya L Hoskin, Kenneth J Cherry.   

Abstract

Strict morphologic criteria must be used for patient selection to achieve durable success with endovascular aortic aneurysm repair (EVAR). The goal of this study was to assess morphologic suitability (MS) of abdominal aortic aneurysms (AAAs) for 2 currently approved bifurcated stent grafts and identify reasons for exclusion from EVAR. The authors reviewed the electronic charts of 1,795 consecutive patients who were diagnosed as having AAA between January 1999 and July 2001 at their institution. Three hundred and twenty patients had an AAA with a diameter of > or = 5.0 cm, measured on computed tomography (CT). The records of 301 patients, 254 men, 47 women, with a mean age of 74 years were available for review, and these patients constituted the study cohort. Criteria used for MS included a proximal neck length > or = 15 mm; neck diameter between 18 and 26 mm; neck angulation < or = 60 degrees ; common or external iliac artery (CIA or EIA) diameters of 7-16 mm and 8-13 mm, respectively, for AneuRx (Medtronic Ave, Santa Rosa, CA) and Ancure (Guidant Cardiac and Vascular Division, Menlo Park, CA) bifurcated grafts. AAAs were suitable for AneuRx device in 14% of patients (43 of 301; 95% CI = 11-19%) and for Ancure in 5% (16 of 301; 95% CI = 3.1-9%). The main reason for exclusion was an inadequate proximal aortic neck (73%). The neck was too short in 49.5%, too wide in 64% and badly angulated in 12% of the patients. Iliac artery morphology precluded EVAR with AneuRx and Ancure devices in 52% and 80%. Both CIAs were too wide for EVAR in 43% and 77%, respectively. When iliac artery diameter < or = 20 mm was accepted, iliac suitability for AneuRx increased from 49% to 70% and overall suitability increased from 14% to 20%. When more permissive criteria were used for MS (neck length > or = 10 mm, neck diameter < or = 30 mm, CIA < or = 20), 39% of patients became candidates for EVAR. More than three fourths of the patients with an AAA > or = 5.0 cm in size, seen in a tertiary referral center, are morphologically not suitable for EVAR using 2 currently approved bifurcated endografts. The main reasons for exclusion are a short or wide proximal aortic neck. Considerable changes in size of the devices and in proximal attachment techniques have to occur before most AAAs will be suitable for EVAR.

Entities:  

Mesh:

Year:  2004        PMID: 15490036     DOI: 10.1177/153857440403800502

Source DB:  PubMed          Journal:  Vasc Endovascular Surg        ISSN: 1538-5744            Impact factor:   1.089


  7 in total

1.  Devices used for endovascular aneurysm repair: past, present, and future.

Authors:  Benjamin M Jackson; Jeffrey P Carpenter
Journal:  Semin Intervent Radiol       Date:  2009-03       Impact factor: 1.513

2.  Initial experience of branched endovascular graft for abdominal aortic aneurysm with complex anatomy of proximal neck: planning and technical considerations.

Authors:  Wataru Higashiura; Takeshi Nagata; Nobuoki Tabayashi; Hirofumi Itoh; Shoji Sakaguchi; Shigeki Taniguchi; Kimihiko Kichikawa; Hideo Uchida
Journal:  Jpn J Radiol       Date:  2010-01-30       Impact factor: 2.374

3.  Endovascular aneurysm repair with the Ovation TriVascular Stent Graft System utilizing a predominantly percutaneous approach under local anaesthesia.

Authors:  C V Ioannou; N Kontopodis; E Kehagias; A Papaioannou; A Kafetzakis; G Papadopoulos; D Pantidis; D Tsetis
Journal:  Br J Radiol       Date:  2015-05-12       Impact factor: 3.039

4.  Abdominal aortic aneurysm neck morphology: proposed classification system.

Authors:  C O McDonnell; M Halak; A Bartlett; S R Baker
Journal:  Ir J Med Sci       Date:  2006 Jul-Sep       Impact factor: 1.568

5.  Two cases of endovascular abdominal aortic aneurysm repair with iliac aneurysm using a zenith iliac bifurcation graft.

Authors:  Kei Kazuno; Norifumi Ohtani; Sentaro Nakanishi
Journal:  Ann Vasc Dis       Date:  2012-11-30

6.  Suitability of the Aortic Neck Anatomy for Endovascular Aneurysm Repair in Korean Patients with Abdominal Aortic Aneurysm.

Authors:  Deokbi Hwang; Jihye Kim; Hyung-Kee Kim; Seung Huh
Journal:  Vasc Specialist Int       Date:  2020-06-30

7.  Limited feasibility in endovascular aneurysm repair using currently available graft in Korea.

Authors:  Taeseok Bae; Taeseung Lee; In Mok Jung; Jongwon Ha; Jung Kee Chung; Sang Joon Kim
Journal:  J Korean Med Sci       Date:  2008-08       Impact factor: 2.153

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.