Literature DB >> 15489489

Incremental nature of anterior eye grading scales determined by objective image analysis.

J S Wolffsohn1.   

Abstract

AIM: To use previously validated image analysis techniques to determine the incremental nature of printed subjective anterior eye grading scales.
METHODS: A purpose designed computer program was written to detect edges using a 3 x 3 kernal and to extract colour planes in the selected area of an image. Annunziato and Efron pictorial, and CCLRU and Vistakon-Synoptik photographic grades of bulbar hyperaemia, palpebral hyperaemia roughness, and corneal staining were analysed.
RESULTS: The increments of the grading scales were best described by a quadratic rather than a linear function. Edge detection and colour extraction image analysis for bulbar hyperaemia (r2 = 0.35-0.99), palpebral hyperaemia (r2 = 0.71-0.99), palpebral roughness (r2 = 0.30-0.94), and corneal staining (r2 = 0.57-0.99) correlated well with scale grades, although the increments varied in magnitude and direction between different scales. Repeated image analysis measures had a 95% confidence interval of between 0.02 (colour extraction) and 0.10 (edge detection) scale units (on a 0-4 scale).
CONCLUSION: The printed grading scales were more sensitive for grading features of low severity, but grades were not comparable between grading scales. Palpebral hyperaemia and staining grading is complicated by the variable presentations possible. Image analysis techniques are 6-35 times more repeatable than subjective grading, with a sensitivity of 1.2-2.8% of the scale.

Entities:  

Mesh:

Year:  2004        PMID: 15489489      PMCID: PMC1772388          DOI: 10.1136/bjo.2004.045534

Source DB:  PubMed          Journal:  Br J Ophthalmol        ISSN: 0007-1161            Impact factor:   4.638


  21 in total

1.  Clinical grading and the effects of scaling.

Authors:  I L Bailey; M A Bullimore; T W Raasch; H R Taylor
Journal:  Invest Ophthalmol Vis Sci       Date:  1991-02       Impact factor: 4.799

2.  Clinical monitoring of ocular physiology using digital image analysis.

Authors:  James S Wolffsohn; Christine Purslow
Journal:  Cont Lens Anterior Eye       Date:  2003-03       Impact factor: 3.077

3.  Grading scales for contact lens complications.

Authors:  N Efron
Journal:  Ophthalmic Physiol Opt       Date:  1998-03       Impact factor: 3.117

4.  A new computer assisted objective method for quantifying vascular changes of the bulbar conjunctivae.

Authors:  C G Owen; F W Fitzke; E G Woodward
Journal:  Ophthalmic Physiol Opt       Date:  1996-09       Impact factor: 3.117

5.  Analysis of microvascular network in bulbar conjunctiva by image processing.

Authors:  P C Chen; S W Kovalcheck; B W Zweifach
Journal:  Int J Microcirc Clin Exp       Date:  1987-08

6.  Slit lamp classification system.

Authors:  R B Mandell
Journal:  J Am Optom Assoc       Date:  1987-03

7.  Validation of grading scales for contact lens complications.

Authors:  N Efron; P B Morgan; S S Katsara
Journal:  Ophthalmic Physiol Opt       Date:  2001-01       Impact factor: 3.117

8.  Key factors in the subjective and objective assessment of conjunctival erythema.

Authors:  E B Papas
Journal:  Invest Ophthalmol Vis Sci       Date:  2000-03       Impact factor: 4.799

9.  Image analysis of conjunctival hyperemia. A personal computer based system.

Authors:  J Villumsen; J Ringquist; A Alm
Journal:  Acta Ophthalmol (Copenh)       Date:  1991-08

10.  Evaluation of the range of areas of the fluorescein staining patterns of the tarsal conjunctiva in man.

Authors:  M J Doughty; R Potvin; N Pritchard; D Fonn
Journal:  Doc Ophthalmol       Date:  1995       Impact factor: 2.379

View more
  9 in total

1.  The effect of digital image resolution and compression on anterior eye imaging.

Authors:  R C Peterson; J S Wolffsohn
Journal:  Br J Ophthalmol       Date:  2005-07       Impact factor: 4.638

2.  Sensitivity and reliability of objective image analysis compared to subjective grading of bulbar hyperaemia.

Authors:  Rachael Claire Peterson; James Stuart Wolffsohn
Journal:  Br J Ophthalmol       Date:  2007-05-02       Impact factor: 4.638

3.  Automated hyperemia analysis software: reliability and reproducibility in healthy subjects.

Authors:  Tsuyoshi Yoneda; Tamaki Sumi; Ayako Takahashi; Yasuhiro Hoshikawa; Masahiko Kobayashi; Atsuki Fukushima
Journal:  Jpn J Ophthalmol       Date:  2011-12-01       Impact factor: 2.447

4.  Exposure study on chemosensory effects of epsilon-caprolactam in the low concentration range.

Authors:  A E Ziegler; H Zimmer; G Triebig
Journal:  Int Arch Occup Environ Health       Date:  2007-10-09       Impact factor: 3.015

5.  A Novel Automated Approach for Infrared-Based Assessment of Meibomian Gland Morphology.

Authors:  Clara Llorens-Quintana; Laura Rico-Del-Viejo; Piotr Syga; David Madrid-Costa; D Robert Iskander
Journal:  Transl Vis Sci Technol       Date:  2019-08-02       Impact factor: 3.283

6.  Objective Assessment of Ocular Surface Response to Contact Lens Wear in Presbyopic Contact Lens Wearers of Asian Descent.

Authors:  Michel Guillon; Kathy Dumbleton; Panagiotis Theodoratos; Trisha Patel; Tom Karkkainen; Kurt Moody
Journal:  Eye Contact Lens       Date:  2018-05       Impact factor: 2.018

7.  A novel scale for describing corneal staining.

Authors:  Jill Woods; Jalaiah Varikooty; Desmond Fonn; Lyndon W Jones
Journal:  Clin Ophthalmol       Date:  2018-11-19

8.  Comparison of different smartphone cameras to evaluate conjunctival hyperaemia in normal subjects.

Authors:  Carles Otero; Nery García-Porta; Juan Tabernero; Shahina Pardhan
Journal:  Sci Rep       Date:  2019-02-04       Impact factor: 4.379

9.  Automated grading system for evaluation of ocular redness associated with dry eye.

Authors:  John D Rodriguez; Patrick R Johnston; George W Ousler; Lisa M Smith; Mark B Abelson
Journal:  Clin Ophthalmol       Date:  2013-06-20
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.