Literature DB >> 15489099

Acute and chronic reduction of functional mitral regurgitation in experimental heart failure by percutaneous mitral annuloplasty.

Calin V Maniu1, Jeetendra B Patel, David G Reuter, Donna M Meyer, William D Edwards, Charanjit S Rihal, Margaret M Redfield.   

Abstract

OBJECTIVES: We sought to determine acute and chronic efficacy of a percutaneous mitral annuloplasty (PMA) device in experimental heart failure (HF). Further, we evaluated the potential for adverse effects on left ventricular (LV) function and coronary perfusion.
BACKGROUND: Reduction of mitral annular dimension with a PMA device in the coronary sinus may reduce functional mitral regurgitation (MR) in advanced HF.
METHODS: Study 1: a PMA device was placed acutely in anesthetized open-chest dogs with rapid pacing-induced HF (n = 6) instrumented for pressure volume analysis. Study 2: in 12 anesthetized dogs with HF, fluoroscopic-guided PMA was performed, and dogs were followed for four weeks with continuing rapid pacing.
RESULTS: Study 1: percutaneous mitral annuloplasty reduced annular dimension and severity of MR at baseline and with phenylephrine infusion to increase afterload (MR jet/left atrial [LA] area 26 +/- 1% to 7 +/- 2%, p < 0.05). Pressure volume analysis demonstrated no acute impairment of LV function. Study 2: no device was placed in two dogs because of prototype size limitations. Attempted PMA impaired coronary flow in three dogs. Percutaneous mitral annuloplasty (n = 7) acutely reduced MR (MR jet/LA area 43 +/- 4% to 8 +/- 5%, p < 0.0001), regurgitant volume (14.7 +/- 2.1 ml to 3.1 +/- 0.5 ml, p < 0.05), effective regurgitant orifice area (0.130 +/- 0.010 cm(2) to 0.040 +/- 0.003 cm(2), p < 0.05), and angiographic MR grade (2.8 +/- 0.3 device to 1.0 +/- 0.3 device, p < 0.001). In the conscious state, MR was reduced at four weeks after PMA (MR jet/LA area 33 +/- 3% HF baseline vs. 11 +/- 4% four weeks after device, p < 0.05)
CONCLUSIONS: Percutaneous mitral annuloplasty results in acute and chronic reduction of functional MR in experimental HF.

Entities:  

Mesh:

Year:  2004        PMID: 15489099     DOI: 10.1016/j.jacc.2004.03.085

Source DB:  PubMed          Journal:  J Am Coll Cardiol        ISSN: 0735-1097            Impact factor:   24.094


  23 in total

1.  Current status of percutaneous valvular procedures.

Authors:  Dominique Himbert; Eric Brochet; David Messika-Zeitoun; Alec Vahanian
Journal:  Curr Treat Options Cardiovasc Med       Date:  2006-11

2.  Comparison of biaxial mechanical properties of coronary sinus tissues from porcine, ovine and aged human species.

Authors:  Thuy Pham; Wei Sun
Journal:  J Mech Behav Biomed Mater       Date:  2011-09-22

3.  True mitral annulus diameter is underestimated by two-dimensional echocardiography as evidenced by real-time three-dimensional echocardiography and magnetic resonance imaging.

Authors:  Ashraf M Anwar; Osama I I Soliman; Folkert J ten Cate; Attila Nemes; Jackie S McGhie; Boudewijn J Krenning; Robert-Jan van Geuns; Tjebbe W Galema; Marcel L Geleijnse
Journal:  Int J Cardiovasc Imaging       Date:  2006-12-13       Impact factor: 2.357

Review 4.  Peri-procedural imaging for transcatheter mitral valve replacement.

Authors:  Navin Natarajan; Parag Patel; Thomas Bartel; Samir Kapadia; Jose Navia; William Stewart; E Murat Tuzcu; Paul Schoenhagen
Journal:  Cardiovasc Diagn Ther       Date:  2016-04

5.  Characterization of the mechanical properties of the coronary sinus for percutaneous transvenous mitral annuloplasty.

Authors:  Thuy Pham; Wei Sun
Journal:  Acta Biomater       Date:  2010-06-01       Impact factor: 8.947

6.  Tension to passively cinch the mitral annulus through coronary sinus access: an ex vivo study in ovine model.

Authors:  Shamik Bhattacharya; Thuy Pham; Zhaoming He; Wei Sun
Journal:  J Biomech       Date:  2014-02-06       Impact factor: 2.712

7.  Emerging approaches of transcatheter valve repair/insertion.

Authors:  Maurizio Taramasso; Micaela Cioni; Andrea Giacomini; Iassen Michev; Cosmo Godino; Matteo Montorfano; Antonio Colombo; Ottavio Alfieri; Francesco Maisano
Journal:  Cardiol Res Pract       Date:  2010-07-25       Impact factor: 1.866

8.  Percutaneous approaches to mitral regurgitation.

Authors:  Faisal Alqoofi; Ted Feldman
Journal:  Curr Treat Options Cardiovasc Med       Date:  2009-12

Review 9.  The role of imaging in percutaneous mitral valve repair.

Authors:  Philipp Kahlert; Björn Plicht; Rolf Alexander Jánosi; Markus Kamler; Hilmar Kühl; Holger Eggebrecht; Stefan Sack; Thomas Buck; Thomas Konorza; Raimund Erbel
Journal:  Herz       Date:  2009-09       Impact factor: 1.443

Review 10.  [Percutaneous mitral valve annuloplasty with the carillon mitral contour system by cardiac dimensions. A minimally invasive therapeutic option for the treatment of severe functional mitral valve regurgitation].

Authors:  Hubertus Degen; Thomas Lickfeld; Carsten Stoepel; Michael Haude
Journal:  Herz       Date:  2009-09       Impact factor: 1.443

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.