Literature DB >> 1548381

Marginal adaptation of four tooth-coloured inlay systems in vivo.

B Van Meerbeek1, S Inokoshi, G Willems, M J Noack, M Braem, P Lambrechts, J F Roulet, G Vanherle.   

Abstract

This study investigates the margin quality of four different tooth-coloured inlay systems using computer-aided quantitative margin analysis under scanning electron microscopy. Three types of restorations involved chairside procedures using a commercial CAD-CAM apparatus: one type of inlay restoration was milled from preformed glass ceramic blocks, the other two inlay types were milled from preformed porcelain blocks. The fourth system was based on an experimental indirect composite inlay system. Each inlay type was luted with its respective dual-curing luting composite, which was supplied with the system. After 6 months of clinical service, all four systems revealed a significant percentage of submargination indicating occlusal wear of the luting composite. The porcelain inlays and the composite inlays luted with their respective experimental luting composite showed the best marginal adaptation. Luted glass ceramic inlays, in particular, suffered from a significantly higher percentage of inlay margin fractures (9 per cent) and marginal openings (4 per cent) than the other systems. A possible explanation is that the glass ceramic subsurface structure at the inlay-lute interface was weakened by etching with ammonium bifluoride.

Entities:  

Mesh:

Substances:

Year:  1992        PMID: 1548381     DOI: 10.1016/0300-5712(92)90004-v

Source DB:  PubMed          Journal:  J Dent        ISSN: 0300-5712            Impact factor:   4.379


  3 in total

1.  The influence of the cavity preparation design on marginal accuracy of laboratory-processed resin composite restorations.

Authors:  Rodrigo Borges Fonseca; Lourenço Correr-Sobrinho; Alfredo Júlio Fernandes-Neto; Paulo Sérgio Quagliatto; Carlos José Soares
Journal:  Clin Oral Investig       Date:  2007-08-10       Impact factor: 3.573

2.  Mechanical interactions of cuspal-coverage designs and cement thickness in a cusp-replacing ceramic premolar restoration: a finite element study.

Authors:  Yen-Hsiang Chang; Wen-Hsueng Lin; Wen-Chieh Kuo; Chia-Yu Chang; Chun-Li Lin
Journal:  Med Biol Eng Comput       Date:  2008-08-05       Impact factor: 2.602

3.  Effect of seating forces on cement-ceramic adhesion in microtensile bond tests.

Authors:  Susana María Salazar Marocho; Mutlu Ozcan; Regina Amaral; Luiz Felipe Valandro; Marco Antonio Bottino
Journal:  Clin Oral Investig       Date:  2012-01-13       Impact factor: 3.573