Literature DB >> 15482457

Optimizing RF output for cooled RF ablation.

William G Stevenson1, Joshua Cooper, John Sapp.   

Abstract

Cooled RF ablation catheters increase lesion size and facilitate ablation compared to standard RF ablation catheters. Cooling the ablation electrode increases the disparity between tissue temperature and electrode temperature, making use of temperature for guiding power application during ablation of less certain value. Appropriate energy titration is important, however, to produce large lesions, while avoiding overheating of tissue with steam formation leading to "pops." In addition to power, the rate of irrigant flow can be controlled. Electrode-tissue contact and orientation and the cooling effect of blood flow around the electrode and within the tissue are not as easily adjusted and also influence tissue heating. In addition to electrode temperature, a decrease in impedance, bubble formation detected by intracardiac ultrasound, and evidence of tissue heating from an effect on recorded electrograms or the arrhythmia can be used to guide ablation energy. Guidelines for adjusting power delivery and avoiding "pops" and coagulum formation are suggested.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15482457     DOI: 10.1046/j.1540-8167.2004.15105.x

Source DB:  PubMed          Journal:  J Cardiovasc Electrophysiol        ISSN: 1045-3873


  4 in total

Review 1.  Optimal ablation strategies for different types of ventricular tachycardias.

Authors:  Takumi Yamada; G Neal Kay
Journal:  Nat Rev Cardiol       Date:  2012-05-29       Impact factor: 32.419

2.  Open-irrigated laser catheter ablation: influence of catheter irrigation and of contact and noncontact mode of laser application on lesion formation in bovine myocardium.

Authors:  Helmut P Weber; Michaela Sagerer-Gerhardt
Journal:  Lasers Med Sci       Date:  2013-12-11       Impact factor: 3.161

3.  Impact of Variableorientation and Flow Rates on Radiofrequency Ablation Lesions Created by Externally Irrigated Catheters: An Ex-Vivo Study.

Authors:  Nishaki Mehta; Katerina Morgaenko; William Sauer; William Stevenson; David Haines
Journal:  J Atr Fibrillation       Date:  2020-10-31

4.  Comparison of real-world clinical and economic outcomes between the ThermoCool® SF and ThermoCool® catheters in patients undergoing radiofrequency catheter ablation for atrial fibrillation.

Authors:  Larry Chinitz; Laura J Goldstein; Andrea Barnow; Sonia Maccioni; Mehmet Daskiran; Iftekhar Kalsekar; Rahul Khanna
Journal:  Clinicoecon Outcomes Res       Date:  2018-10-04
  4 in total