Literature DB >> 15481838

Computed tomographic assessment of the trachea in the German shepherd dog.

Mehmet Erkut Kara1, Erkut Turan, Ilknur Dabanoglu, Mehmet Kamil Ocal.   

Abstract

Computed tomographic (CT) examination of the trachea was performed in 10 German shepherd dogs to determine the normal value of some tracheal measurements under general anesthesia and in sternal recumbence position. Measurements obtained from nine segments were evaluated in four groups as the cranial cervical, caudal cervical, thoracic inlet and the thoracal tracheas. The inner transverse (T) and vertical (V) diameters were measured with the aid of electronic calipers from the software of the CT scanner. The cross-sectional lumen area (CSA) was calculated by using vertical and transverse diameters. The ratio of the transverse and vertical diameters (T/V) was also calculated. There was not any significant difference between thoracic inlet and thoracic tracheas, however, the mentioned regions were found to be significantly different from both cranial and caudal cervical regions in all measurements except the ratio of T/V. The ratio of T/V between 0.92 and 1.06 gradually changed and there was not any statistical difference between subsequent regions while differences were found among further regions. The largest CSA, seen in cranial cervical trachea was as 364.62 mm2 and decreased gradually to 309.29, 245.69 and 226.50 mm2 in caudal cervical, thoracic inlet and thoracic tracheas, respectively. From the point of view of technique, CT examination of the dog trachea was very easy and it was possible to take sensitive and repeated measurements. It, however, may be accepted as expensive and that it is disadvantageous to require general anesthesia. The data presented in this study represent tracheal values in the healthy German shepherd dog under the conditions of the study.

Entities:  

Mesh:

Year:  2004        PMID: 15481838     DOI: 10.1016/S0940-9602(04)80048-7

Source DB:  PubMed          Journal:  Ann Anat        ISSN: 0940-9602            Impact factor:   2.698


  6 in total

1.  COMPARISON OF FLUOROSCOPY AND COMPUTED TOMOGRAPHY FOR TRACHEAL LUMEN DIAMETER MEASUREMENT AND DETERMINATION OF INTRALUMINAL STENT SIZE IN HEALTHY DOGS.

Authors:  Jackie M Williams; Ingar A Krebs; Elizabeth A Riedesel; Qianqian Zhao
Journal:  Vet Radiol Ultrasound       Date:  2016-01-19       Impact factor: 1.363

2.  Three-dimensional reconstruction of New Zealand rabbit antebrachium by multidetector computed tomography.

Authors:  S Özkadif; E Eken; K Beşoluk; M O Dayan
Journal:  Iran J Vet Res       Date:  2015       Impact factor: 1.376

3.  3D bioprinting of a trachea-mimetic cellular construct of a clinically relevant size.

Authors:  Jeong Hun Park; Minjun Ahn; Sun Hwa Park; Hyeonji Kim; Mihyeon Bae; Wonbin Park; Scott J Hollister; Sung Won Kim; Dong-Woo Cho
Journal:  Biomaterials       Date:  2021-11-10       Impact factor: 12.479

4.  Correlations among tracheal dimensions, tracheal stent dimensions, and major complications after endoluminal stenting of tracheal collapse syndrome in dogs.

Authors:  Nathaniel P Violette; Chick Weisse; Allyson C Berent; Kenneth E Lamb
Journal:  J Vet Intern Med       Date:  2019-07-09       Impact factor: 3.333

5.  Tracheal growth assessment in mongrel puppies (dogs) through multidetector CT.

Authors:  Rosa Eugenia Soriano-Rosales; Beatriz Eugenia Pérez-Guillé; Miguel Angel Jimenez-Bravo-Luna; Susana Monroy-Santoyo; Fernándo Villegas-Alvarez; Arturo Carmona-Mancilla; Carlos Jiménez-Gutiérrez; Susana Leticia Elizalde-Velázquez; Jose Francisco Gonzalez-Zamora
Journal:  Vet Rec Open       Date:  2018-03-09

6.  Radiographic vertical tracheal diameter assessment at different levels along the trachea as an alternative method for the evaluation of the tracheal diameter in non-brachycephalic small breed dogs.

Authors:  Ayman A Mostafa; Clifford R Berry
Journal:  BMC Vet Res       Date:  2022-02-01       Impact factor: 2.741

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.