Literature DB >> 15480041

Periodically rotated overlapping parallel lines with enhanced reconstruction-based diffusion tensor imaging. Comparison with echo planar imaging-based diffusion tensor imaging.

Osamu Abe1, Harushi Mori, Shigeki Aoki, Akira Kunimatsu, Naoto Hayashi, Tomohiko Masumoto, Haruyasu Yamada, Yoshitaka Masutani, Hiroyuki Kabasawa, Kuni Ohtomo.   

Abstract

OBJECTIVE: To evaluate diffusion tensor imaging (DTI) based on periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER) compared with DTI based on single-shot echo planar imaging (EPI).
METHODS: Diffusion tensor data were acquired with PROPELLER (PROPELLER-DTI, 3 NEX), EPI (EPI-DTI2, 16 NEX) with the same acquisition time (11.4 minutes) and with EPI (EPI-DTI1, number of excitations = 4) with a shorter acquisition time (2.8 minutes). Regions of interest were set in the genu and splenium of the corpus callosum, as determined on T2-weighted fast spin echo images and fractional anisotropy (FA) maps, separately. Two neuroradiologists visually evaluated image distortion and quality in the supra- and infratentorial structures.
RESULTS: In the genu, standard deviation determined by respective FA maps was decreased in order of PROPELLER-DTI, EPI-DTI1, and EPI-DTI2. Both EPI-DTI sequences were quantitatively superior in the splenium, but PROPELLER-DTI was less distorted.
CONCLUSION: Periodically rotated overlapping parallel lines with enhanced reconstruction-DTI could become a complementary tool when qualitatively evaluating seriously distorted structures.

Entities:  

Mesh:

Year:  2004        PMID: 15480041     DOI: 10.1097/01.rct.0000138008.85349.28

Source DB:  PubMed          Journal:  J Comput Assist Tomogr        ISSN: 0363-8715            Impact factor:   1.826


  4 in total

1.  Voxel-based analysis of the diffusion tensor.

Authors:  Osamu Abe; Hidemasa Takao; Wataru Gonoi; Hiroki Sasaki; Mizuho Murakami; Hiroyuki Kabasawa; Hiroshi Kawaguchi; Masami Goto; Haruyasu Yamada; Hidenori Yamasue; Kiyoto Kasai; Shigeki Aoki; Kuni Ohtomo
Journal:  Neuroradiology       Date:  2010-05-14       Impact factor: 2.804

Review 2.  Diffusion tensor MR imaging and fiber tractography: technical considerations.

Authors:  P Mukherjee; S W Chung; J I Berman; C P Hess; R G Henry
Journal:  AJNR Am J Neuroradiol       Date:  2008-03-13       Impact factor: 3.825

3.  Detection of middle ear cholesteatoma by diffusion-weighted MR imaging: multishot echo-planar imaging compared with single-shot echo-planar imaging.

Authors:  K Yamashita; T Yoshiura; A Hiwatashi; H Kamano; T Dashjamts; S Shibata; A Tamae; H Honda
Journal:  AJNR Am J Neuroradiol       Date:  2011-07-21       Impact factor: 3.825

4.  3T PROPELLER diffusion tensor fiber tractography: a feasibility study for cranial nerve fiber tracking.

Authors:  Hiroyuki Kabasawa; Yoshitaka Masutani; Shigeki Aoki; Osamu Abe; Tomohiko Masumoto; Naoto Hayashi; Kuni Ohtomo
Journal:  Radiat Med       Date:  2007-11-26
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.