Literature DB >> 15479446

Influence of hydration and experimental length scale on the mechanical response of human skin in vivo, using optical coherence tomography.

F M Hendriks1, D Brokken, C W J Oomens, F P T Baaijens.   

Abstract

BACKGROUNDS/AIMS: Human skin is a complex tissue consisting of different layers. To gain better insight into the mechanical behaviour of different skin layers, the mechanical response was studied with experiments of various length scales. Also, the influence of (superficial) hydration on the mechanical response is studied. The work is based on the hypothesis that experiments with different length scales represent the mechanical behaviour of different skin layers. For suction, this means that a large aperture diameter reflects the behaviour of mainly dermis, whereas a very small diameter reflects the behaviour of only the top layer of the skin.
METHODS: Suction measurements at varying pressures and aperture sizes were performed on the volar forearm of 13 subjects aged 29-47 years. The deformation of the skin was visualized using ultrasound (US) (dermis) and optical coherence tomography (OCT) (epidermis and dermis). US measurements were performed on hydrated skin, OCT measurements on dry and hydrated skin. The experiment was simulated by a finite element model (FEM) exhibiting extended Mooney material behaviour. An identification method was used to compare the experimental and numerical results to identify the parameters of the material.
RESULTS: The material parameters C(10) and C(11) were calculated for four subjects: C(10)=29.6+/-21.1 kPa and C(11)=493+/-613 kPa for 6 mm aperture diameter, C(10)=11.5+/-8.7 kPa and C(11)=18.3+/-12.6 kPa for 2 mm aperture diameter and C(10)=10.8+/-9.5 kPa and C(11)=9.3+/-7.7 kPa for 1 mm aperture diameter. Skin hydration caused ambiguous effects on the mechanical response.
CONCLUSIONS: US and OCT, combined with suction, using varying apertures sizes, proved to be a valuable tool to study the mechanical behaviour of different skin layers. With increasing experimental length scale, increasing values for the parameters of the material model were found. This indicates the need of a multi-layered material layer FEM, which can be used to identify mechanical behaviour of epidermis and dermis.

Entities:  

Mesh:

Year:  2004        PMID: 15479446     DOI: 10.1111/j.1600-0846.2004.00077.x

Source DB:  PubMed          Journal:  Skin Res Technol        ISSN: 0909-752X            Impact factor:   2.365


  10 in total

1.  Optimization of microdermabrasion for controlled removal of stratum corneum.

Authors:  Samantha N Andrews; Vladimir Zarnitsyn; Brian Bondy; Mark R Prausnitz
Journal:  Int J Pharm       Date:  2011-01-25       Impact factor: 5.875

2.  Epidermal electronics: Skin health monitoring.

Authors:  Stéphanie P Lacour
Journal:  Nat Mater       Date:  2015-07       Impact factor: 43.841

3.  Finite element simulations of the head-brain responses to the top impacts of a construction helmet: Effects of the neck and body mass.

Authors:  John Z Wu; Christopher S Pan; Bryan M Wimer; Charles L Rosen
Journal:  Proc Inst Mech Eng H       Date:  2016-12-21       Impact factor: 1.617

4.  An improved finite element modeling of the cerebrospinal fluid layer in the head impact analysis.

Authors:  John Z Wu; Christopher S Pan; Bryan M Wimer; Charles L Rosen
Journal:  Biomed Mater Eng       Date:  2017       Impact factor: 1.300

5.  Preliminary Results on the Feasibility of Using ARFI/SWEI to Assess Cutaneous Sclerotic Diseases.

Authors:  Seung Yun Lee; Adela R Cardones; Joshua Doherty; Kathryn Nightingale; Mark Palmeri
Journal:  Ultrasound Med Biol       Date:  2015-08-08       Impact factor: 2.998

6.  Biomechanical properties of in vivo human skin from dynamic optical coherence elastography.

Authors:  Xing Liang; Stephen A Boppart
Journal:  IEEE Trans Biomed Eng       Date:  2009-10-09       Impact factor: 4.538

7.  In vivo three-dimensional optical coherence elastography.

Authors:  Brendan F Kennedy; Xing Liang; Steven G Adie; Derek K Gerstmann; Bryden C Quirk; Stephen A Boppart; David D Sampson
Journal:  Opt Express       Date:  2011-03-28       Impact factor: 3.894

8.  Rehydration capacities and rates for various porcine tissues after dehydration.

Authors:  Jacob P Meyer; Kieran E McAvoy; Jack Jiang
Journal:  PLoS One       Date:  2013-09-04       Impact factor: 3.240

9.  Complexity, rate, and scale in sliding friction dynamics between a finger and textured surface.

Authors:  Behnam Khojasteh; Marco Janko; Yon Visell
Journal:  Sci Rep       Date:  2018-09-12       Impact factor: 4.379

10.  Vibration analysis of healthy skin: toward a noninvasive skin diagnosis methodology.

Authors:  Rakshita Panchal; Luke Horton; Peyman Poozesh; Javad Baqersad; Mohammadreza Nasiriavanaki
Journal:  J Biomed Opt       Date:  2019-01       Impact factor: 3.170

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.