| Literature DB >> 15478449 |
Xiufen Gong1, Dong Zhang, Jiehui Liu, Huanlei Wang, Yongsheng Yan, Xiaochen Xu.
Abstract
Three novel methods for acoustic nonlinearity parameter B/A imaging in reflection mode are developed in this paper. They are: (1) the acoustic nonlinearity parameter B/A tomography by detecting reflective second harmonic wave, (2) the B/A tomography in reflection mode via the measurement of the difference frequency wave generated by a parametric array, and (3) the C-scan imaging of B/A via the measurement of the echo second-harmonic signal. A theoretical analysis and the experimental imaging of normal and pathological biological tissues by using these methods are also present and discussed. Results show that using the acoustic nonlinearity parameter imaging we can more easily distinguish the diseased tissue from the normal one than using the linear acoustic parameters.Mesh:
Year: 2004 PMID: 15478449 DOI: 10.1121/1.1781709
Source DB: PubMed Journal: J Acoust Soc Am ISSN: 0001-4966 Impact factor: 1.840