Literature DB >> 15476960

The use of a 3D laser scanner using superimpositional software to assess the accuracy of impression techniques.

Sinal Shah1, Geeta Sundaram, David Bartlett, Martyn Sherriff.   

Abstract

OBJECTIVE: Several studies have made comparisons in the dimensional accuracy of different elastomeric impression materials. Most have used two-dimensional measuring devices, which neglect to account for the dimensional changes that exist along a three-dimensional surface.
PURPOSE: The aim of this study was to compare the dimensional accuracy of an impression technique using a polyether material (Impregum) and a vinyl poly siloxane material (President) using a laser scanner with three-dimensional superimpositional software.
MATERIALS AND METHODS: Twenty impressions, 10 with a polyether and 10 with addition silicone, of a stone master model that resembled a dental arch containing three acrylic posterior teeth were cast in orthodontic stone. One plastic tooth was prepared for a metal crown. The master model and the casts were digitised with the non-contacting laser scanner to produce a 3D image. 3D surface viewer software superimposed the master model to the stone replica and the difference between the images analysed.
RESULTS: The mean difference between the model and the stone replica made from Impregum was 0.072mm (SD 0.006) and that for the silicone 0.097mm (SD 0.005) and this difference was statistically significantly, p=0.001.
CONCLUSIONS: Both impression materials provided an accurate replica of the prepared teeth supporting the view that these materials are highly accurate.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15476960     DOI: 10.1016/j.jdent.2004.07.005

Source DB:  PubMed          Journal:  J Dent        ISSN: 0300-5712            Impact factor:   4.379


  5 in total

1.  Digital assessment of properties of the three different generations of dental elastomeric impression materials.

Authors:  Lamia Singer; Shaymaa I Habib; Heba El-Amin Shalaby; Sayed H Saniour; Christoph Bourauel
Journal:  BMC Oral Health       Date:  2022-09-05       Impact factor: 3.747

2.  In vivo evaluation of inter-operator reproducibility of digital dental and conventional impression techniques.

Authors:  Emi Kamimura; Shinpei Tanaka; Masayuki Takaba; Keita Tachi; Kazuyoshi Baba
Journal:  PLoS One       Date:  2017-06-21       Impact factor: 3.240

3.  Influence of chloramine-T disinfection on elastomeric impression stability.

Authors:  Ricardo Danil Guiraldo; Sandrine Bittencourt Berger; Marilia Franco Punhagui; Thais Staut Moretto; Murilo Baena Lopes; Alcides Gonini-Júnior; Mário Alexandre Coelho Sinhoreti
Journal:  Eur J Dent       Date:  2018 Apr-Jun

4.  Effect of rinsing time on the accuracy of interim crowns fabricated by digital light processing: An in vitro study.

Authors:  Beom-Il Lee; Seung-Gyu You; Seung-Min You; Seen-Young Kang; Ji-Hwan Kim
Journal:  J Adv Prosthodont       Date:  2021-02-23       Impact factor: 1.904

5.  Evaluation of Elastomeric Impression Materials' Hydrophilicity: An in vitro Study.

Authors:  Anna Theocharidou; Konstantinos Tzimas; Kosmas Tolidis; Dimitrios Tortopidis
Journal:  Acta Stomatol Croat       Date:  2021-09
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.