Abstract

OBJECTIVES: The performance of both light-curing and dual-cured adhesive/luting systems (as control), when used in combination with translucent fibre posts, was evaluated by means of pull-out test and scanning electron microscopy (SEM ) observation.
METHODS: Forty root canal treated teeth were randomly divided into two groups of 20 specimens each. Group 1 light-curing system: Excite and Tetric Flow; Group 2 dual cured system: All Bond 2+RelyX ARC. Translucent, double taper fibre posts were used (2.1/1.4mm diameter). The teeth were stored in NaCl 0.9% solution at 37 degrees C. A week later, the pull-out test was carried out on all specimens. Ten tested specimens for each group and their corresponding posts were processed for SEM observation. Statistical analysis was performed applying one-way analysis of variance (ANOVA) followed by T-test as post-hoc comparison at a significance level set at p<0.05.
RESULTS: There is no statistically significant difference (p>0.05) between the light-curing system group (275.2+/-58.9N) and the dual cured one (301.4+/-40.1N). SEM observations confirm a good bond between the dentine and the post whatever the curing method employed.
CONCLUSIONS: Dual curing of the All Bond 2+RelyX ARC system seems to be the most appropriate method since it allows to cure even those areas which would not be otherwise reached by light. On the other hand, in apical areas, the incomplete curing of the Excite+Tetric Flow system could improve the post adaptation and allow the achievement of both an improved apical seal and a more even distribution of the stress along the canal walls.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15476957     DOI: 10.1016/j.jdent.2004.06.004

Source DB:  PubMed          Journal:  J Dent        ISSN: 0300-5712            Impact factor:   4.379


  4 in total

1.  Can cement film thickness influence bond strength and fracture resistance of fiber reinforced composite posts?

Authors:  Alice Gonçalves Penelas; Valery Martins Piedade; Ana Carolina Oliveira da Silva Borges; Laiza Tatiana Poskus; Eduardo Moreira da Silva; José Guilherme Antunes Guimarães
Journal:  Clin Oral Investig       Date:  2015-08-29       Impact factor: 3.573

2.  Microhardness of different resin cement shades inside the root canal.

Authors:  Valeria Vignolo; Maria-Victoria Fuentes; Miguel-Angel Garrido; Jesús Rodríguez; Laura Ceballos
Journal:  Med Oral Patol Oral Cir Bucal       Date:  2012-09-01

3.  Microhardness of dual-polymerized resin cement around a translucent fiber post in the intraradicular environment.

Authors:  Mutlu Ozcan; Sandra Zambonι; Felipe Valandro; Marco Bottino; Bora Bagis
Journal:  J Conserv Dent       Date:  2011-10

4.  Effect of Light Intensity on the Degree of Conversion of Dual-cured Resin Cement at Different Depths with the use of Translucent Fiber Posts.

Authors:  Mahmoud Bahari; Siavash Savadi Oskoee; Soodabeh Kimyai; Narmin Mohammadi; Elmira Saati Khosroshahi
Journal:  J Dent (Tehran)       Date:  2014-05-31
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.