Literature DB >> 15476753

Inhibitory effect of low-dose estrogen on neointimal formation after balloon injury of rat carotid artery.

Tokumitsu Watanabe1, Yukiko Miyahara, Masahiro Akishita, Takashi Nakaoka, Naohide Yamashita, Katsuya Iijima, Hong Kim, Koichi Kozaki, Yasuyoshi Ouchi.   

Abstract

The current regimens of hormone replacement therapy for postmenopausal women, estrogen combined with progestogen, have failed to show beneficial effects for the prevention of atherosclerotic disease. Although the relatively higher dose of estrogen contained in those regimens exerted adverse effects, there are few data examining a lower dose of estrogen in an atherosclerosis model. Therefore, we investigated experimentally whether lower doses of estrogen could inhibit neointimal formation after balloon injury of the rat carotid artery. Ten-week-old Wistar rats were subjected to ovariectomy or sham-operation (n=7). Four days after ovariectomy, rats were implanted with an osmotic mini-pump containing 17-beta estradiol (0.2, 1, 2, 10 and 20 microg/kg/day; n=6, 4, 8, 6 and 5, respectively) or placebo (n=10). After 3 days of hormone therapy, balloon injury was performed in the left common carotid artery. Neointimal formation was histologically evaluated 2 weeks after injury. Cross-sectional intimal area and the ratio of intimal area to medial area were dose-dependently reduced by estrogen replacement compared with those in ovariectomized rats without estrogen replacement. The effects of estrogen replacement were identical to those of an angiotensin II type 1 receptor blocker, candesartan. Interestingly, the effect was significant even in rats receiving lower doses of estrogen, in which plasma estradiol concentrations were not increased and the hyperplastic response of the uterus was minimal. These results suggest the efficacy of low-dose estrogen therapy for the protection of atherosclerosis.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15476753     DOI: 10.1016/j.ejphar.2004.09.011

Source DB:  PubMed          Journal:  Eur J Pharmacol        ISSN: 0014-2999            Impact factor:   4.432


  2 in total

1.  Reduced intimal hyperplasia in rabbits via medical therapy after carotid venous bypass.

Authors:  Semih Yucel; Muzaffer Bahcivan; Mehmet Kamil Gol; Behice H Erenler; Fersat Kolbakir; Hasan T Keceligil
Journal:  Tex Heart Inst J       Date:  2009

2.  Sex differences in arterial identity correlate with neointimal hyperplasia after balloon injury.

Authors:  Mingjie Gao; Xixiang Gao; Ryosuke Taniguchi; Anand Brahmandam; Yutaka Matsubara; Jia Liu; Hao Liu; Weichang Zhang; Alan Dardik
Journal:  Mol Biol Rep       Date:  2022-06-17       Impact factor: 2.742

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.