Literature DB >> 15475589

Double tether extraction from human neutrophils and its comparison with CD4+ T-lymphocytes.

Gang Xu1, Jin-Yu Shao.   

Abstract

The initial arrest and subsequent rolling of a leukocyte on the vascular endothelium is believed to be facilitated by the extraction of tethers, which are narrow membranous tubes drawn from the leukocyte. Although single tether extraction from neutrophils has been studied thoroughly, the relationship between the tether force (F) and tether-growth velocity (U(t)) is still unknown for double tethers drawn from neutrophils. In this study, we have determined this relationship with the micropipette-aspiration technique. As a comparison, tether extraction from CD4+ T-lymphocytes was also studied. The threshold force and effective viscosity for single tether extraction from passive CD4+ T-lymphocytes were found to be 46 pN and 1.55 pN x s/microm, respectively. These values were modulated by stimulation with phorbol myristate acetate (PMA), but not interleukin-8 (IL-8). More importantly, for both types of leukocyte, the threshold force and effective viscosity for double tether extraction are about twice as large as those corresponding to single tether extraction. Neither IL-8 nor PMA stimulation had any effect on this correlation. These results indicate that double tethers are highly localized on cellular surfaces and independent of each other during the rolling process.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15475589      PMCID: PMC1305043          DOI: 10.1529/biophysj.104.048363

Source DB:  PubMed          Journal:  Biophys J        ISSN: 0006-3495            Impact factor:   4.033


  31 in total

1.  Correlating the kinetics of cytokine-induced E-selectin adhesion and expression on endothelial cells.

Authors:  J D Levin; H P Ting-Beall; R M Hochmuth
Journal:  Biophys J       Date:  2001-02       Impact factor: 4.033

2.  A sensitive measure of surface stress in the resting neutrophil.

Authors:  D Needham; R M Hochmuth
Journal:  Biophys J       Date:  1992-06       Impact factor: 4.033

3.  Comparison of PSGL-1 microbead and neutrophil rolling: microvillus elongation stabilizes P-selectin bond clusters.

Authors:  Eric Y H Park; McRae J Smith; Emily S Stropp; Karen R Snapp; Jeffrey A DiVietro; William F Walker; David W Schmidtke; Scott L Diamond; Michael B Lawrence
Journal:  Biophys J       Date:  2002-04       Impact factor: 4.033

4.  Measurement of the elastic modulus for red cell membrane using a fluid mechanical technique.

Authors:  R M Hochmuth; N Mohandas; P L Blackshear
Journal:  Biophys J       Date:  1973-08       Impact factor: 4.033

5.  Surface viscosity measurements from large bilayer vesicle tether formation. II. Experiments.

Authors:  R E Waugh
Journal:  Biophys J       Date:  1982-04       Impact factor: 4.033

6.  Extensional flow of erythrocyte membrane from cell body to elastic tether. II. Experiment.

Authors:  R M Hochmuth; H C Wiles; E A Evans; J T McCown
Journal:  Biophys J       Date:  1982-07       Impact factor: 4.033

7.  Mechanical anchoring strength of L-selectin, beta2 integrins, and CD45 to neutrophil cytoskeleton and membrane.

Authors:  J Y Shao; R M Hochmuth
Journal:  Biophys J       Date:  1999-07       Impact factor: 4.033

8.  Direct observation of membrane tethers formed during neutrophil attachment to platelets or P-selectin under physiological flow.

Authors:  D W Schmidtke; S L Diamond
Journal:  J Cell Biol       Date:  2000-05-01       Impact factor: 10.539

9.  P-selectin glycoprotein ligand-1 mediates rolling of human neutrophils on P-selectin.

Authors:  K L Moore; K D Patel; R E Bruehl; F Li; D A Johnson; H S Lichenstein; R D Cummings; D F Bainton; R P McEver
Journal:  J Cell Biol       Date:  1995-02       Impact factor: 10.539

10.  Distinct molecular and cellular contributions to stabilizing selectin-mediated rolling under flow.

Authors:  Tadayuki Yago; Anne Leppänen; Haiying Qiu; Warren D Marcus; Matthias U Nollert; Cheng Zhu; Richard D Cummings; Rodger P McEver
Journal:  J Cell Biol       Date:  2002-08-12       Impact factor: 10.539

View more
  17 in total

1.  An integrated stochastic model of "inside-out" integrin activation and selective T-lymphocyte recruitment.

Authors:  Michael T Beste; Dooyoung Lee; Michael R King; Gary A Koretzky; Daniel A Hammer
Journal:  Langmuir       Date:  2012-01-04       Impact factor: 3.882

Review 2.  Biomechanics of leukocyte rolling.

Authors:  Prithu Sundd; Maria K Pospieszalska; Luthur Siu-Lun Cheung; Konstantinos Konstantopoulos; Klaus Ley
Journal:  Biorheology       Date:  2011       Impact factor: 1.875

3.  Cell membrane tethers generate mechanical force in response to electrical stimulation.

Authors:  William E Brownell; Feng Qian; Bahman Anvari
Journal:  Biophys J       Date:  2010-08-04       Impact factor: 4.033

4.  Multiple membrane tethers probed by atomic force microscopy.

Authors:  Mingzhai Sun; John S Graham; Balazs Hegedüs; Françoise Marga; Ying Zhang; Gabor Forgacs; Michel Grandbois
Journal:  Biophys J       Date:  2005-09-23       Impact factor: 4.033

5.  Simultaneous tether extraction contributes to neutrophil rolling stabilization: a model study.

Authors:  Yan Yu; Jin-Yu Shao
Journal:  Biophys J       Date:  2006-10-27       Impact factor: 4.033

6.  Double-tether extraction from human umbilical vein and dermal microvascular endothelial cells.

Authors:  Gaurav Girdhar; Yong Chen; Jin-Yu Shao
Journal:  Biophys J       Date:  2006-11-10       Impact factor: 4.033

7.  Effect of temperature on tether extraction, surface protrusion, and cortical tension of human neutrophils.

Authors:  Baoyu Liu; Craig J Goergen; Jin-Yu Shao
Journal:  Biophys J       Date:  2007-06-22       Impact factor: 4.033

8.  Simultaneous tether extraction from endothelial cells and leukocytes: observation, mechanics, and significance.

Authors:  Gaurav Girdhar; Jin-Yu Shao
Journal:  Biophys J       Date:  2007-08-17       Impact factor: 4.033

9.  Control of cell membrane tension by myosin-I.

Authors:  Rajalakshmi Nambiar; Russell E McConnell; Matthew J Tyska
Journal:  Proc Natl Acad Sci U S A       Date:  2009-07-02       Impact factor: 11.205

10.  Human neutrophil surface protrusion under a point load: location independence and viscoelasticity.

Authors:  Gang Xu; Jin-Yu Shao
Journal:  Am J Physiol Cell Physiol       Date:  2008-09-24       Impact factor: 4.249

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.