Literature DB >> 15473687

Integrated protein microchip assay with dual fluorescent- and MALDI read-out.

D Finnskog1, A Ressine, T Laurell, G Marko-Varga.   

Abstract

A pore chip protein array (PCPA) concept based on a dual readout configuration, fluorescence imaging, and MALDI-TOF MS has been developed. Highly packed, (>4000 spots/cm2), antibody arrays were dispensed on the porous chip by using a piezo-electric microdispenser. Sandwich assay was made after blocking by addition of a secondary antibody either IgG-FITC-labeled or anti-Ang II. The antigen in the first system was a large protein (IgG), and in the other system, a FITC marked peptide Angiotensin II (Ang II) was used. Ang II antibodies showed specificity for Ang II, while the Ang I antibodies showed binding properties for Ang I, II, and Renin. Fluorescence and MALDI TOF MS read-out was made for IgG and Ang II. A major advantage of the dual read-out PCPA approach is that both affinity binding and mass identity are derived. Detection limits for Ang II on the chip is as low as 500 zmol (Ang II).

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15473687     DOI: 10.1021/pr0499287

Source DB:  PubMed          Journal:  J Proteome Res        ISSN: 1535-3893            Impact factor:   4.466


  5 in total

1.  Efficient sample preparation in immuno-matrix-assisted laser desorption/ionization mass spectrometry using acoustic trapping.

Authors:  Björn Hammarström; Hong Yan; Johan Nilsson; Simon Ekström
Journal:  Biomicrofluidics       Date:  2013-03-28       Impact factor: 2.800

2.  Porous silicon antibody microarrays for quantitative analysis: measurement of free and total PSA in clinical plasma samples.

Authors:  Kerstin Järås; Belinda Adler; Axel Tojo; Johan Malm; György Marko-Varga; Hans Lilja; Thomas Laurell
Journal:  Clin Chim Acta       Date:  2012-08-18       Impact factor: 3.786

3.  macroMS: Image-Guided Analysis of Random Objects by Matrix-Assisted Laser Desorption/Ionization Time-of-Flight Mass Spectrometry.

Authors:  Kisurb Choe; Pu Xue; Huimin Zhao; Jonathan V Sweedler
Journal:  J Am Soc Mass Spectrom       Date:  2021-04-06       Impact factor: 3.109

4.  A Highly Sensitive Porous Silicon (P-Si)-Based Human Kallikrein 2 (hK2) Immunoassay Platform toward Accurate Diagnosis of Prostate Cancer.

Authors:  Sang Wook Lee; Kazuo Hosokawa; Soyoun Kim; Ok Chan Jeong; Hans Lilja; Thomas Laurell; Mizuo Maeda
Journal:  Sensors (Basel)       Date:  2015-05-22       Impact factor: 3.576

5.  Hybrid Integrated Silicon Microfluidic Platform for Fluorescence Based Biodetection.

Authors:  Arvind Chandrasekaran; Ashwin Acharya; Jian Liang You; Kim Young Soo; Muthukumaran Packirisamy; Ion Stiharu; André Darveau
Journal:  Sensors (Basel)       Date:  2007-09-11       Impact factor: 3.576

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.