Literature DB >> 15468944

Multi-detector row helical CT of the liver: quantitative assessment of iodine concentration of intravenous contrast material on multiphasic CT--a prospective randomized study.

Masakatsu Tsurusaki1, Koji Sugimoto, Masahiko Fujii, Kazuro Sugimura.   

Abstract

PURPOSE: The purpose of this study was to assess the quantitative effects of contrast material concentration on hepatic parenchymal and vascular enhancement in multiphasic computed tomography (CT), using multi-detector row helical CT.
MATERIALS AND METHODS: We designed a prospective randomized study to test two different concentrations of contrast material on five phasic scans of the liver. One hundred patients were randomly assigned to two groups: an iodine concentration of 300 mg/mL in group A and 370 mg/mL in group B. All patients received a fixed volume of 100 mL at a 4 mL/sec injection rate. Enhancement values for the hepatic parenchyma and aorta at three levels (upper, middle, and lower level of the liver), and values for portal and hepatic veins were statistically compared between the two groups.
RESULTS: Hepatic parenchymal enhancement values at all levels of the liver in portal phase (PP) and equilibrium phase (EP) were significantly higher in group B than in group A (p<0.01). Aortic enhancement values at two levels of the liver (middle and lower) in early hepatic arterial phase (EAP) were significantly higher in group B than in group A (p<0.05), however, there was no significant difference between groups A and B in aortic enhancement during the delayed hepatic arterial phase (DAP). Portal and hepatic venous enhancement values in PP and EP were significantly higher in group B than in group A (p<0.01).
CONCLUSION: On multiphasic dynamic CT, the use of a higher iodine concentration of contrast material results in higher hepatic parenchymal enhancement and aortic enhancement, as well as higher portal and hepatic venous enhancement.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15468944

Source DB:  PubMed          Journal:  Radiat Med        ISSN: 0288-2043


  7 in total

1.  Optimizing scan timing of hepatic arterial phase by physiologic pharmacokinetic analysis in bolus-tracking technique by multi-detector row computed tomography.

Authors:  Isao Yamaguchi; Eiji Kidoya; Masayuki Suzuki; Hirohiko Kimura
Journal:  Radiol Phys Technol       Date:  2010-09-25

2.  Contrast enhancement in multidetector-row computed tomography (MDCT) of the abdomen: intraindividual comparison of contrast media containing 300 mg versus 370 mg iodine per ml.

Authors:  F F Behrendt; A H Mahnken; S Keil; M Das; C Hohl; D Bauer; P Seidensticker; E Jost; J E Wildberger; R W Günther; G Mühlenbruch
Journal:  Eur Radiol       Date:  2008-01-29       Impact factor: 5.315

3.  A comparison of the use of contrast media with different iodine concentrations for multidetector CT of the kidney.

Authors:  Seung Chai Jung; Seung Hyup Kim; Jeong Yeon Cho
Journal:  Korean J Radiol       Date:  2011-09-27       Impact factor: 3.500

4.  Adaptive statistical iterative reconstruction for volume-rendered computed tomography portovenography: improvement of image quality.

Authors:  Izuru Matsuda; Shohei Hanaoka; Masaaki Akahane; Jiro Sato; Shuuhei Komatsu; Shinichi Inoh; Shigeru Kiryu; Naoki Yoshioka; Kenji Ino; Kuni Ohtomo
Journal:  Jpn J Radiol       Date:  2010-11-27       Impact factor: 2.374

5.  Which Iodine concentration in chest CT?--a prospective study in 300 patients.

Authors:  Georg Mühlenbruch; Florian F Behrendt; Mohammed A Eddahabi; Christian Knackstedt; Sven Stanzel; Marco Das; Peter Seidensticker; Rolf W Günther; Joachim E Wildberger; Andreas H Mahnken
Journal:  Eur Radiol       Date:  2008-07-24       Impact factor: 5.315

6.  Effects of High-concentration contrast material and low-voltage CT on contrast for multiphasic CT of the upper abdomen: comparison using the simulation with virtual monochromatic imaging obtained by fast-switch kVp dual-energy CT.

Authors:  Makoto Sakane; Tonsok Kim; Masatoshi Hori; Hiromitsu Onishi; Atsushi Nakamoto; Takahiro Tsuboyama; Mitsuaki Tatsumi; Noriyuki Tomiyama
Journal:  Springerplus       Date:  2014-05-08

7.  Comparison of enhancement and image quality: different iodine concentrations for liver on 128-slice multidetector computed tomography in the same chronic liver disease patients.

Authors:  Byoung Goo Jo; Yun Gyu Song; Sang Goon Shim; Young Wook Kim
Journal:  Korean J Intern Med       Date:  2015-12-23       Impact factor: 2.884

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.