Literature DB >> 15468327

Enumeration of antigen-specific CD8+ T lymphocytes by single-platform, HLA tetramer-based flow cytometry: a European multicenter evaluation.

Ingmar A F M Heijnen1, David Barnett, Maria J Arroz, Simon M Barry, Marc Bonneville, Bruno Brando, Jean-Luc D'hautcourt, Florian Kern, Thomas H Tötterman, Erik W A Marijt, David Bossy, Frank W M B Preijers, Gregor Rothe, Jan W Gratama.   

Abstract

BACKGROUND: HLA class I peptide tetramers represent powerful diagnostic tools for detection and monitoring of antigen-specific CD8(+) T cells. The impetus for the current multicenter study is the critical need to standardize tetramer flow cytometry if it is to be implemented as a routine diagnostic assay. Hence, the European Working Group on Clinical Cell Analysis set out to develop and evaluate a single-platform tetramer-based method that used cytomegalovirus (CMV) as the antigenic model.
METHODS: Absolute numbers of CMV-specific CD8(+) T cells were obtained by combining the percentage of tetramer-binding cells with the absolute CD8(+) T-cell count. Six send-outs of stabilized blood from healthy individuals or CMV-carrying donors with CMV-specific CD8(+) T-cell counts of 3 to 10 cells/microl were distributed to 7 to 16 clinical sites. These sites were requested to enumerate CD8(+) T cells and, in the case of CMV-positive donors, CMV-specific subsets on three separate occasions using the standard method.
RESULTS: Between-site coefficients of variation of less than 10% (absolute CD8(+) T-cell counts) and approximately 30% (percentage and absolute numbers of CMV-specific CD8(+) T cells) were achieved. Within-site coefficients of variation were approximately 5% (absolute CD8(+) T-cell counts), approximately 9% (percentage CMV-specific CD8(+) T cells), and approximately 17% (absolute CMV-specific CD8(+) T-cell counts). The degree of variation tended to correlate inversely with the proportion of CMV-specific CD8(+) T-cell subsets.
CONCLUSIONS: The single-platform MHC tetramer-based method for antigen-specific CD8(+) T-cell counting has been evaluated by a European group of laboratories and can be considered a reproducible assay for routine enumeration of antigen-specific CD8(+) T cells. (c) 2004 Wiley-Liss, Inc.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15468327     DOI: 10.1002/cyto.b.20028

Source DB:  PubMed          Journal:  Cytometry B Clin Cytom        ISSN: 1552-4949            Impact factor:   3.058


  6 in total

1.  Soluble MHC-peptide complexes: tools for the monitoring of T cell responses in clinical trials and basic research.

Authors:  Philippe Guillaume; Danijel Dojcinovic; Immanuel F Luescher
Journal:  Cancer Immun       Date:  2009-09-25

2.  Relationship between cytomegalovirus (CMV) IgG serology, detectable CMV DNA in peripheral monocytes, and CMV pp65(495-503)-specific CD8+ T cells in older adults.

Authors:  Sean X Leng; Tao Qu; Richard D Semba; Huifen Li; Xu Yao; Tricia Nilles; Xi Yang; Bhavish Manwani; Jeremy D Walston; Luigi Ferrucci; Linda P Fried; Joseph B Margolick; Jay H Bream
Journal:  Age (Dordr)       Date:  2011-01-28

3.  Data analysis as a source of variability of the HLA-peptide multimer assay: from manual gating to automated recognition of cell clusters.

Authors:  Cécile Gouttefangeas; Cliburn Chan; Sebastian Attig; Tania T Køllgaard; Hans-Georg Rammensee; Stefan Stevanović; Dorothee Wernet; Per thor Straten; Marij J P Welters; Christian Ottensmeier; Sjoerd H van der Burg; Cedrik M Britten
Journal:  Cancer Immunol Immunother       Date:  2015-02-18       Impact factor: 6.968

4.  Sequential anti-cytomegalovirus response monitoring may allow prediction of cytomegalovirus reactivation after allogeneic stem cell transplantation.

Authors:  Sylvia Borchers; Melanie Bremm; Thomas Lehrnbecher; Elke Dammann; Brigitte Pabst; Benno Wölk; Ruth Esser; Meral Yildiz; Matthias Eder; Michael Stadler; Peter Bader; Hans Martin; Andrea Jarisch; Gisbert Schneider; Thomas Klingebiel; Arnold Ganser; Eva M Weissinger; Ulrike Koehl
Journal:  PLoS One       Date:  2012-12-13       Impact factor: 3.240

5.  Harmonization guidelines for HLA-peptide multimer assays derived from results of a large scale international proficiency panel of the Cancer Vaccine Consortium.

Authors:  Cedrik Michael Britten; Sylvia Janetzki; Leah Ben-Porat; Timothy M Clay; Michael Kalos; Holden Maecker; Kunle Odunsi; Michael Pride; Lloyd Old; Axel Hoos; Pedro Romero
Journal:  Cancer Immunol Immunother       Date:  2009-03-04       Impact factor: 6.968

6.  The CIMT-monitoring panel: a two-step approach to harmonize the enumeration of antigen-specific CD8+ T lymphocytes by structural and functional assays.

Authors:  C M Britten; C Gouttefangeas; M J P Welters; G Pawelec; S Koch; C Ottensmeier; A Mander; S Walter; A Paschen; J Müller-Berghaus; I Haas; A Mackensen; T Køllgaard; P thor Straten; M Schmitt; K Giannopoulos; R Maier; H Veelken; C Bertinetti; A Konur; C Huber; S Stevanović; T Wölfel; S H van der Burg
Journal:  Cancer Immunol Immunother       Date:  2007-08-25       Impact factor: 6.968

  6 in total