Literature DB >> 15465549

Digital stereoscopic analysis of the optic disc: evaluation of a teaching program.

Nicholas J L Sheen1, James E Morgan, Johan L Poulsen, Rachel V North.   

Abstract

PURPOSE: To determine if a computer-based stereoscopic teaching program could improve optic cup/disc ratio (CDR) agreement between student observers and an expert.
DESIGN: Experimental study. PARTICIPANTS: Six student observers (A-F) assessed at least 30 digital stereoscopic optic disc images using a digital stereoscopic analysis program. All observers made 36 CDR measurements (every 10 degrees ) for each disc image that they assessed.
METHODS: Disc images were divided into 3 sets of 10 images (image sets 1, 2, and 3). Observers A, B, and C determined CDRs for all 3 image sets. Set 1 was examined without access to a teaching program, set 2 using a teaching program that allowed the observer to view an expert assessment of the optic disc, and set 3 after using the teaching program. Observers D, E, and F evaluated image sets 1 and 3 only and did not have access to the teaching program. Ten months later, these same observers (D-F) viewed image set 2 using the teaching program and then reassessed image set 3. MAIN OUTCOME MEASURES: Standard deviation (SD) of CDR differences between observers and an expert, the percentage of CDR observations differing > or =0.20 from those of the expert, and intraclass correlation coefficients (ICCs) between observers.
RESULTS: Before teaching, the average SD of differences between all observers and the expert was 0.10. After teaching, the average SD of differences between all observers and the expert was 0.057. For observers D, E, and F, the average SD of differences for image set 3 without teaching was 0.074. The percentage of all observer measurements that differed > or =0.20 from those of the expert for image set 1 was 16.7%; for set 3 after teaching, 1.7%; and for set 3 for observers D, E, and F without teaching, 10%. Interobserver ICC values for all observers were 0.37 before teaching and 0.76 after. For observers D, E, and F, the ICC value for set 3 without access to teaching was 0.69.
CONCLUSIONS: This study suggests that an interactive digital stereoscopic teaching program improves agreement between observers and an expert when assessing CDRs.

Entities:  

Mesh:

Year:  2004        PMID: 15465549     DOI: 10.1016/j.ophtha.2004.04.018

Source DB:  PubMed          Journal:  Ophthalmology        ISSN: 0161-6420            Impact factor:   12.079


  4 in total

1.  Automated assessment of the optic nerve head on stereo disc photographs.

Authors:  Juan Xu; Hiroshi Ishikawa; Gadi Wollstein; Richard A Bilonick; Kyung R Sung; Larry Kagemann; Kelly A Townsend; Joel S Schuman
Journal:  Invest Ophthalmol Vis Sci       Date:  2008-03-07       Impact factor: 4.799

2.  Agreement between optical coherence tomography and digital stereophotography in vertical cup-to-disc ratio measurement.

Authors:  Giacomo Savini; Edgar M Espana; Ana Carolina Acosta; Michele Carbonelli; Costantino Bellusci; Piero Barboni
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2008-10-29       Impact factor: 3.117

3.  Agreement in assessing cup-to-disc ratio measurement among stereoscopic optic nerve head photographs, HRT II, and Stratus OCT.

Authors:  Stella N Arthur; Aric J Aldridge; Julio De León-Ortega; Gerald McGwin; Aiyuan Xie; Christopher A Girkin
Journal:  J Glaucoma       Date:  2006-06       Impact factor: 2.503

4.  The effect of education on the assessment of optic nerve head photographs for the glaucoma diagnosis.

Authors:  Sabina Andersson; Anders Heijl; Andreas G Boehm; Boel Bengtsson
Journal:  BMC Ophthalmol       Date:  2011-05-19       Impact factor: 2.209

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.