Literature DB >> 15464678

Usefulness of high-pressure post-dilatation to optimize deployment of drug-eluting stents for the treatment of diffuse in-stent coronary restenosis.

Daniel J Blackman1, Italo Porto, Cheerag Shirodaria, Keith M Channon, Adrian P Banning.   

Abstract

Drug-eluting stents (DESs) may represent a simple, effective treatment for in-stent restenosis (ISR); however, the underexpansion of stents is a significant cause of target vessel failure. It was hypothesized that high-pressure postdilatation would be necessary to optimize DES expansion and minimize the risk for restenosis when treating patients with ISR. Fifteen patients with diffuse ISR were treated by predilatation (including cutting balloons), DES deployment, and high-pressure postdilatation, with the measurement of luminal and stent dimensions by intravascular ultrasound after each intervention. After initial deployment, DES underexpansion was present in 10 of 15 patients (66%); after high-pressure postdilatation, there was a significant increase in luminal dimensions, including minimum luminal area (4.3 +/- 0.3 to 5.6 +/- 0.4 mm(2), p <0.001) and a doubling in the proportion of patients with optimal stent expansion. At long-term follow-up (median 11 months), target lesion revascularization occurred in 1 patient (7%) because of edge restenosis; there was no restenosis within the DES.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15464678     DOI: 10.1016/j.amjcard.2004.06.029

Source DB:  PubMed          Journal:  Am J Cardiol        ISSN: 0002-9149            Impact factor:   2.778


  4 in total

Review 1.  Current understanding of coronary in-stent restenosis. Pathophysiology, clinical presentation, diagnostic work-up, and management.

Authors:  T M Schiele
Journal:  Z Kardiol       Date:  2005-11

2.  Differential effects of post-dilation after stent deployment in patients presenting with and without acute myocardial infarction.

Authors:  Zhi-Jiang Zhang; Oscar C Marroquin; Roslyn A Stone; Joel L Weissfeld; Suresh R Mulukutla; Faith Selzer; Kevin E Kip
Journal:  Am Heart J       Date:  2010-11       Impact factor: 4.749

3.  Effect of balloon inflation time on expansion of sirolimus-eluting stent.

Authors:  Tatsuhiko Asano; Yoshio Kobayashi; Kenichi Fukushima; Yo Iwata; Hideki Kitahara; Naoki Ishio; Takashi Nakayama; Nakabumi Kuroda; Issei Komuro
Journal:  Heart Vessels       Date:  2009-09-27       Impact factor: 2.037

4.  Effect of stent inflation pressure and post-dilatation on the outcome of coronary artery intervention. A report of more than 90,000 stent implantations.

Authors:  Ole Fröbert; Giovanna Sarno; Stefan K James; Nawsad Saleh; Bo Lagerqvist
Journal:  PLoS One       Date:  2013-02-13       Impact factor: 3.240

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.