BACKGROUND: The anterior mitral annulus is considered a fixed structure. Recent data suggest otherwise. This study tested the hypothesis that the size of the anterior annulus varies with hemodynamic loading and ventricular contractility. METHODS: Sonomicrometry array localization measured annular area, total annular circumference, anterior circumference, and posterior circumference in 6 sheep before and after neosynephrine increased systolic blood pressure by at least 150% during atrial pacing at 120 beats/min. In 6 additional animals the same dimensions were measured during atrial pacing (at 120 and 150 beats/min) and during isoproteronol infusions to increase heart rate to 120 and 150 beats/min. RESULTS: Neosynephrine increased systolic total annular circumference from 99.7 +/- 5.5 mm to 106.9 +/- 9.6 mm. Anterior circumference increased from 40.8 +/- 4.0 mm to 45.3 +/- 5.7 mm whereas posterior circumference only increased from 59.0 +/- 5.5 mm to 61.6 +/- 7.0 mm. Low isoproteronol infusion decreased systolic total annular circumference from 107.5 +/- 8.3 mm to 101.9 +/- 10.6 mm. Most of this change occurred in the posterior circumference. Higher infusions of isoproteronol decreased total annular circumference from 106.8 +/- 8.3 mm to 98.3 +/- 9.7 mm. At this higher inotropic state the decrease in annular size was similar in the anterior and posterior annulus. CONCLUSIONS: In sheep, the anterior annulus is a dynamic structure that varies in size in response to changes in hemodynamic loading and ventricular contractility.
BACKGROUND: The anterior mitral annulus is considered a fixed structure. Recent data suggest otherwise. This study tested the hypothesis that the size of the anterior annulus varies with hemodynamic loading and ventricular contractility. METHODS: Sonomicrometry array localization measured annular area, total annular circumference, anterior circumference, and posterior circumference in 6 sheep before and after neosynephrine increased systolic blood pressure by at least 150% during atrial pacing at 120 beats/min. In 6 additional animals the same dimensions were measured during atrial pacing (at 120 and 150 beats/min) and during isoproteronol infusions to increase heart rate to 120 and 150 beats/min. RESULTS:Neosynephrine increased systolic total annular circumference from 99.7 +/- 5.5 mm to 106.9 +/- 9.6 mm. Anterior circumference increased from 40.8 +/- 4.0 mm to 45.3 +/- 5.7 mm whereas posterior circumference only increased from 59.0 +/- 5.5 mm to 61.6 +/- 7.0 mm. Low isoproteronol infusion decreased systolic total annular circumference from 107.5 +/- 8.3 mm to 101.9 +/- 10.6 mm. Most of this change occurred in the posterior circumference. Higher infusions of isoproteronol decreased total annular circumference from 106.8 +/- 8.3 mm to 98.3 +/- 9.7 mm. At this higher inotropic state the decrease in annular size was similar in the anterior and posterior annulus. CONCLUSIONS: In sheep, the anterior annulus is a dynamic structure that varies in size in response to changes in hemodynamic loading and ventricular contractility.
Authors: Song Wan; Alex P W Lee; Chun-Na Jin; Randolph H L Wong; Herman H M Chan; Calvin S H Ng; Innes Y P Wan; Malcolm J Underwood Journal: Ann Cardiothorac Surg Date: 2015-05
Authors: Elizabeth H Stephens; Monica M Fahrenholtz; Patrick S Connell; Tomasz A Timek; George T Daughters; Joyce J Kuo; Aaron M Patton; Neil B Ingels; D Craig Miller; K Jane Grande-Allen Journal: Cardiovasc Eng Technol Date: 2015-06 Impact factor: 2.495
Authors: Kamal R Khabbaz; Feroze Mahmood; Omair Shakil; Haider J Warraich; Joseph H Gorman; Robert C Gorman; Robina Matyal; Peter Panzica; Philip E Hess Journal: Ann Thorac Surg Date: 2012-10-25 Impact factor: 4.330
Authors: Liam P Ryan; Benjamin M Jackson; Hirotsuga Hamamoto; Thomas J Eperjesi; Theodore J Plappert; Martin St John-Sutton; Robert C Gorman; Joseph H Gorman Journal: Ann Thorac Surg Date: 2008-09 Impact factor: 4.330
Authors: Akinobu Itoh; Daniel B Ennis; Wolfgang Bothe; Julia C Swanson; Gaurav Krishnamurthy; Tom C Nguyen; Neil B Ingels; D Craig Miller Journal: J Thorac Cardiovasc Surg Date: 2009-09-11 Impact factor: 5.209