Recurrent laryngeal nerve identification and assessment during thyroid surgery: laryngeal palpation.

Gregory W Randolph1, James B Kobler, Jamie Wilkins.   

Abstract

Electrical identification and monitoring of the recurrent laryngeal nerve (RLN) has been proposed as an adjunct to standard visual identification of the nerve during thyroid and parathyroid surgery. This study was undertaken to assess laryngeal palpation as an intraoperative technique for identifying and assessing the RLN during surgery and to investigate the relation between laryngeal palpation and associated laryngeal electromyographic (EMG) activity. The postcricoid region of the larynx during surgery was palpated through the posterior hypopharyngeal wall to sense posterior cricoarytenoid muscle contraction in response to ipsilateral RLN stimulation (i.e., the "laryngeal twitch response.") Laryngeal palpation was performed in a series of 449 consecutive thyroid and parathyroid surgeries with 586 RLNs at risk. All patients underwent preoperative and postoperative laryngoscopy to assess vocal cord mobility. In a subset of patients, laryngeal palpation and simultaneous laryngeal EMG recordings were compared during intraoperative RLN stimulation. In this series, there was no permanent RLN paralysis. There was one case of temporary RLN paralysis secondary to neural stretch that resolved 6 weeks postoperatively (temporary paralysis rate: 0.2% of patients, 0.2% of nerves at risk). Intraoperative laryngeal palpation of the laryngeal twitch response reliably correlated with normal postoperative vocal cord function. Loss of the laryngeal twitch response occurred in the single case of temporary paralysis in the setting of an anatomically intact nerve. Laryngeal palpation correlated well with simultaneous laryngeal EMG activity. There were no palpation-induced laryngeal injuries or laryngeal edema. There were also no RLN injuries due to repetitive neural stimulation. Intraoperative laryngeal palpation during RLN stimulation is a safe, reliable method for neural monitoring that can assist in RLN identification and assessment during thyroid and parathyroid surgery. Most importantly, it provides important prognostic information regarding ipsilateral vocal cord function at the completion of the initial side of the thyroid or parathyroid surgery. Intraoperative laryngeal palpation allows the surgeon to stage contralateral surgery if RLN damage is diagnosed, thereby avoiding the potential for bilateral vocal cord paralysis. We believe that laryngeal palpation is useful as an adjunct to formal EMG monitoring during thyroid and parathyroid surgery.

Entities:  

Mesh:

Year:  2004        PMID: 15457354     DOI: 10.1007/s00268-004-7348-x

Source DB:  PubMed          Journal:  World J Surg        ISSN: 0364-2313            Impact factor:   3.352


  32 in total

1.  A piece of my mind. Moral wounds: complicated complications.

Authors:  S Munch; L deKryger
Journal:  JAMA       Date:  2001-03-07       Impact factor: 56.272

2.  An overview of 711 general surgery liability cases. The anatomy of surgical malpractice claims.

Authors:  K A Kern
Journal:  Bull Am Coll Surg       Date:  1995-08

3.  Intraoperative identification of laryngeal nerves with laryngeal electromyography.

Authors:  M Mermelstein; R Nonweiler; E H Rubinstein
Journal:  Laryngoscope       Date:  1996-06       Impact factor: 3.325

4.  Electrophysiologic nerve stimulation for identifying the recurrent laryngeal nerve in thyroid surgery: review of 70 consecutive thyroid surgeries.

Authors:  A Echeverri; P B Flexon
Journal:  Am Surg       Date:  1998-04       Impact factor: 0.688

5.  Intraoperative monitoring of facial nerve function in cerebellopontine angle surgery.

Authors:  P E Hammerschlag; N L Cohen
Journal:  Otolaryngol Head Neck Surg       Date:  1990-11       Impact factor: 3.497

6.  The effects of surgery, radioiodine, and external radiation therapy on the clinical outcome of patients with differentiated thyroid carcinoma.

Authors:  R W Tsang; J D Brierley; W J Simpson; T Panzarella; M K Gospodarowicz; S B Sutcliffe
Journal:  Cancer       Date:  1998-01-15       Impact factor: 6.860

7.  Clinical outcome of continuous facial nerve monitoring during primary parotidectomy.

Authors:  J E Terrell; P R Kileny; C Yian; R M Esclamado; C R Bradford; M S Pillsbury; G T Wolf
Journal:  Arch Otolaryngol Head Neck Surg       Date:  1997-10

Review 8.  Recurrent nerve palsy after thyroid operations--principal nerve identification and a literature review.

Authors:  G R Jatzko; P H Lisborg; M G Müller; V M Wette
Journal:  Surgery       Date:  1994-02       Impact factor: 3.982

9.  Complications of thyroid surgery.

Authors:  D B de Roy van Zuidewijn; I Songun; J Kievit; C J van de Velde
Journal:  Ann Surg Oncol       Date:  1995-01       Impact factor: 5.344

10.  [Intraoperative facial nerve monitoring in parotid surgery].

Authors:  S R Wolf; W Schneider; B Suchy; B Eichhorn
Journal:  HNO       Date:  1995-05       Impact factor: 1.284

View more
  42 in total

1.  An applied anatomical study on the recurrent laryngeal nerve and inferior thyroid artery.

Authors:  Wen-Jing Tang; Shan-Quan Sun; Xing-Lu Wang; Yu-Xing Sun; Hai-Xia Huang
Journal:  Surg Radiol Anat       Date:  2011-11-29       Impact factor: 1.246

2.  [Intraoperative neuromonitoring of thyroid gland operations : Surgical standards and aspects of expert assessment].

Authors:  H Dralle; K Lorenz
Journal:  Chirurg       Date:  2010-07       Impact factor: 0.955

3.  Is Nerve Monitoring Required in Total Thyroidectomy? Cerrahpasa Experience.

Authors:  Serkan Teksoz; Yusuf Bukey; Murat Ozcan; Akif Enes Arikan; Ates Ozyegin
Journal:  Indian J Surg       Date:  2013-01-31       Impact factor: 0.656

4.  Feasibility of intraoperative neuromonitoring during thyroid surgery after administration of nondepolarizing neuromuscular blocking agents.

Authors:  Koung-Shing Chu; Sheng-Hua Wu; I-Cheng Lu; Cheng-Jing Tsai; Che-Wei Wu; Wen-Rei Kuo; Ka-Wo Lee; Feng-Yu Chiang
Journal:  World J Surg       Date:  2009-07       Impact factor: 3.352

5.  Energy based devices and recurrent laryngeal nerve injury: the need for safer instruments.

Authors:  Gianlorenzo Dionigi
Journal:  Langenbecks Arch Surg       Date:  2008-12-24       Impact factor: 3.445

6.  Complications to thyroid surgery: results as reported in a database from a multicenter audit comprising 3,660 patients.

Authors:  A Bergenfelz; S Jansson; A Kristoffersson; H Mårtensson; E Reihnér; G Wallin; I Lausen
Journal:  Langenbecks Arch Surg       Date:  2008-07-17       Impact factor: 3.445

7.  [Intraoperative neuromonitoring in thyroid surgery. Recommendations of the Surgical Working Group for Endocrinology].

Authors:  H Dralle; K Lorenz; P Schabram; T J Musholt; C Dotzenrath; P E Goretzki; J Kußmann; B Niederle; C Nies; J Schabram; C Scheuba; D Simon; T Steinmüller; A Trupka
Journal:  Chirurg       Date:  2013-12       Impact factor: 0.955

8.  Intraoperative neural monitoring in thyroid cancer surgery.

Authors:  Gregory W Randolph; Dipti Kamani
Journal:  Langenbecks Arch Surg       Date:  2013-11-27       Impact factor: 3.445

9.  Electromyographic response persists after peripheral transection: endorsement of current concepts in recurrent laryngeal nerve monitoring in a porcine model.

Authors:  Torsten Birkholz; Andrea Irouschek; Dirk Labahn; Peter Klein; Joachim Schmidt
Journal:  Langenbecks Arch Surg       Date:  2009-11-25       Impact factor: 3.445

10.  Use of the harmonic scalpel versus conventional haemostatic techniques in patients with Grave disease undergoing total thyroidectomy: a prospective randomised controlled trial.

Authors:  P Hallgrimsson; L Lovén; J Westerdahl; Anders Bergenfelz
Journal:  Langenbecks Arch Surg       Date:  2008-08-02       Impact factor: 3.445

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.