Holter-type impedance cardiography device. A system for continuous and non-invasive monitoring of cardiac haemodynamics.

Gerard Cybulski1, Edward Koźluk, Ewa Michalak, Wiktor Niewiadomski, Agnieszka Piatkowska.   

Abstract

Impedance cardiography (ICG) enables the non-invasive, reproducible, beat-to-beat estimation of stroke volume (SV) changes, and the measurement of the absolute values of the ejection time (ET) and pre-ejection period (PEP), which allows the indirect evaluation of cardiac contractility. The miniaturised, Holter-type impedance cardiography device with built-in one channel of ECG called ReoMonitor, was constructed. The system allows the long-term, beat-to-beat, automatic evaluation of SV, ET, PEP and heart rate. The measurements obtained by ReoMonitor were verified using on echocardiographic method in supine and tilted positions. A high correlation coefficient (r=0.83) was calculated between the measurements collected using both methods. Speech or vigorous movement distinctly lowered the percentage of properly recognised cardiac cycles (during daytime: 20-80%, during the night: 75-90%). However, during exercise testing on a cycloergometer the quality of recordings was good. The following clinical applications of a system are presented: a) evaluation of hemodynamical abnormalities caused by arrhythmia events, b) vasovagal syncope diagnosis, and c) optimisation of atrio-ventricular delay during dual-chamber pacing.

Entities:  

Mesh:

Year:  2004        PMID: 15457280

Source DB:  PubMed          Journal:  Kardiol Pol        ISSN: 0022-9032            Impact factor:   3.108


  3 in total

1.  Antazoline-insights into drug-induced electrocardiographic and hemodynamic effects: Results of the ELEPHANT II substudy.

Authors:  Roman Piotrowski; Joanna Giebułtowicz; Jakub Baran; Agnieszka Sikorska; Dagmara Gralak-Łachowska; Małgorzata Soszyńska; Piotr Wroczyński; Piotr Kułakowski
Journal:  Ann Noninvasive Electrocardiol       Date:  2017-02-25       Impact factor: 1.468

2.  Effect of physical countermaneuvers on orthostatic hypotension in familial dysautonomia.

Authors:  Marcin Tutaj; Harald Marthol; Dena Berlin; Clive M Brown; Felicia B Axelrod; Max J Hilz
Journal:  J Neurol       Date:  2005-08-17       Impact factor: 6.682

3.  Design and Implementation of a Portable Impedance Cardiography System for Noninvasive Stroke Volume Monitoring.

Authors:  Hassan Yazdanian; Amin Mahnam; Mehdi Edrisi; Morteza Abdar Esfahani
Journal:  J Med Signals Sens       Date:  2016 Jan-Mar
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.