Literature DB >> 15456323

Online CE-MALDI-TOF MS using a rotating ball interface.

Harrison K Musyimi1, Damien A Narcisse, Xia Zhang, Wieslaw Stryjewski, Steven A Soper, Kermit K Murray.   

Abstract

We report on the construction and performance of a rotating ball interface for online coupling of capillary electrophoresis (CE) to matrix-assisted laser desorption ionization (MALDI) mass spectrometry with a time-of-flight (TOF) mass analyzer. The interface is based on a rotating stainless steel ball that transports samples from atmospheric pressure to the high vacuum of the mass spectrometer for desorption and ionization. The sample is deposited directly from a 50-microm-i.d. separation capillary onto the 19-mm ball that is rotating at 0.03 to 0.3 rpm. The sample is mixed online with matrix flowing from a separate 50-microm-i.d. capillary. The sample deposit dries before it is rotated past a polymer gasket and into the laser ionization region. Cleaning of the interface is accomplished using solvent-saturated felt, which cleans the ball surface after it rotates out of the ionization chamber. On-line CE-MALDI is demonstrated, and the performance is evaluated with the analysis of a mixture of three peptides: [Lsy8] vasopressin, substance P, and neurotensin. The rotating ball interface to MALDI-TOF MS demonstrated mass detection limit in the high femtomole range. The interface has negligible memory effect and shows no significant electrophoretic peak broadening when operated under optimized conditions.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15456323     DOI: 10.1021/ac0489723

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  7 in total

1.  On-line single droplet deposition for MALDI mass spectrometry.

Authors:  Xia Zhang; Damien A Narcisse; Kermit K Murray
Journal:  J Am Soc Mass Spectrom       Date:  2004-10       Impact factor: 3.109

Review 2.  Analysis of glycans derived from glycoconjugates by capillary electrophoresis-mass spectrometry.

Authors:  Yehia Mechref
Journal:  Electrophoresis       Date:  2011-12       Impact factor: 3.535

3.  Interfacing capillary-based separations to mass spectrometry using desorption electrospray ionization.

Authors:  Griffin K Barbula; Samir Safi; Konstantin Chingin; Richard H Perry; Richard N Zare
Journal:  Anal Chem       Date:  2011-02-14       Impact factor: 6.986

4.  Solid-phase extraction and purification of membrane proteins using a UV-modified PMMA microfluidic bioaffinity μSPE device.

Authors:  Katrina N Battle; Joshua M Jackson; Małgorzata A Witek; Mateusz L Hupert; Sally A Hunsucker; Paul M Armistead; Steven A Soper
Journal:  Analyst       Date:  2014-03-21       Impact factor: 4.616

5.  Capillary electrophoresis coupled to MALDI mass spectrometry imaging with large volume sample stacking injection for improved coverage of C. borealis neuropeptidome.

Authors:  Kellen DeLaney; Lingjun Li
Journal:  Analyst       Date:  2019-12-16       Impact factor: 4.616

6.  CE-MALDI interface based on inkjet technology.

Authors:  Michael W Vannatta; Colin D Whitmore; Norman J Dovichi
Journal:  Electrophoresis       Date:  2009-12       Impact factor: 3.535

7.  Capillary electrophoresis applied to proteomic analysis.

Authors:  Bryan R Fonslow; John R Yates
Journal:  J Sep Sci       Date:  2009-04       Impact factor: 3.645

  7 in total