Literature DB >> 15456316

Anodic stripping voltammetry of arsenic(III) using gold nanoparticle-modified electrodes.

Xuan Dai1, Olga Nekrassova, Michael E Hyde, Richard G Compton.   

Abstract

A novel method for the detection of arsenic(III) in 1 M HCl at a gold nanoparticle-modified glassy carbon electrode has been developed. The gold nanoparticles were electrodeposited onto the glassy carbon electrode via a potential step from +1.055 to -0.045 V vs SCE for 15 s from 0.5 M H2SO4 containing 0.1 mM HAuCl4. The resulting electrode surfaces were characterized with both AFM and cyclic voltammetry. Anodic stripping voltammetry of arsenic(III) on the modified electrode was performed. After optimization, a LOD of 0.0096 ppb was obtained with LSV.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15456316     DOI: 10.1021/ac049232x

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  19 in total

Review 1.  Electrochemical sensors.

Authors:  Eric Bakker; Yu Qin
Journal:  Anal Chem       Date:  2006-06-15       Impact factor: 6.986

Review 2.  Nanomaterial-based electrochemical sensing of neurological drugs and neurotransmitters.

Authors:  Bankim J Sanghavi; Otto S Wolfbeis; Thomas Hirsch; Nathan S Swami
Journal:  Mikrochim Acta       Date:  2014-07-08       Impact factor: 5.833

3.  A nanocomposite consisting of ionic liquid-functionalized layered Mg(II)/Al(III) double hydroxides for simultaneous electrochemical determination of cadmium(II), copper(II), mercury(II) and lead(II).

Authors:  Jianfeng Zhou; Guohan Sun; Jianbin Pan; Yufang Pan; Sumei Wang; Haiyun Zhai
Journal:  Mikrochim Acta       Date:  2019-11-12       Impact factor: 5.833

Review 4.  Modified electrodes used for electrochemical detection of metal ions in environmental analysis.

Authors:  Gregory March; Tuan Dung Nguyen; Benoit Piro
Journal:  Biosensors (Basel)       Date:  2015-04-29

5.  A Third Generation Glucose Biosensor Based on Cellobiose Dehydrogenase Immobilized on a Glassy Carbon Electrode Decorated with Electrodeposited Gold Nanoparticles: Characterization and Application in Human Saliva.

Authors:  Paolo Bollella; Lo Gorton; Roland Ludwig; Riccarda Antiochia
Journal:  Sensors (Basel)       Date:  2017-08-18       Impact factor: 3.576

6.  Synthesis and Characterization of Porous MnCo2O4 for Electrochemical Determination of Cadmium ions in Water Samples.

Authors:  Murugan Velmurugan; Shen-Ming Chen
Journal:  Sci Rep       Date:  2017-04-05       Impact factor: 4.379

7.  A Simple Metallothionein-Based Biosensor for Enhanced Detection of Arsenic and Mercury.

Authors:  Gordon W Irvine; Swee Ngin Tan; Martin J Stillman
Journal:  Biosensors (Basel)       Date:  2017-03-13

8.  Thermally stable hybrid polyarylidene(azomethine-ether)s polymers (PAAP): an ultrasensitive arsenic(III) sensor approach.

Authors:  Mohammed M Rahman; Mahmoud A Hussein; Kamal I Aly; Abdullah M Asiri
Journal:  Des Monomers Polym       Date:  2018-05-22       Impact factor: 2.650

9.  Effect of Nanoparticles on Modified Screen Printed Inhibition Superoxide Dismutase Electrodes for Aluminum.

Authors:  Miriam Barquero-Quirós; María Julia Arcos-Martínez
Journal:  Sensors (Basel)       Date:  2016-09-26       Impact factor: 3.576

10.  Electrochemical Sensing toward Trace As(III) Based on Mesoporous MnFe₂O₄/Au Hybrid Nanospheres Modified Glass Carbon Electrode.

Authors:  Shaofeng Zhou; Xiaojuan Han; Honglei Fan; Yaqing Liu
Journal:  Sensors (Basel)       Date:  2016-06-22       Impact factor: 3.576

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.