Literature DB >> 15456304

Measuring seven endogenous ketolic estrogens simultaneously in human urine by high-performance liquid chromatography-mass spectrometry.

Xia Xu1, Larry K Keefer, David J Waterhouse, Joseph E Saavedra, Timothy D Veenstra, Regina G Ziegler.   

Abstract

A rapid, sensitive, and specific high-performance liquid chromatography-electrospray ionization-multistage mass spectrometry (MS) method for measuring endogenous ketolic estrogen metabolites in human urine has been developed. The method requires a single hydrolysis/extraction/derivatization step and only 2.5 mL of urine, yet is able to simultaneously quantify estrone and its 2-methoxy and 2-, 4-, and 16alpha-hydroxy derivatives, 16-ketoestradiol, and 2-hydroxyestrone-3-methyl ether metabolites. The combination of a simple hydrazone derivatization step with multistage MS greatly enhances the sensitivity and specificity of the analysis of endogenous estrogen within human urine. Standard curves are linear over a 100-fold concentration range with linear regression correlation coefficients typically greater than 0.99. The lower limit of quantitation for each ketolic estrogen is 0.2 ng/2.5-mL urine sample (10 pg on column), with an accuracy of 93-103% and an overall precision, including the hydrolysis, extraction, and derivatization steps, of 1-13% relative standard derivation (RSD) for samples prepared concurrently and 8-16% RSD for samples prepared in separate batches. This method also allows for the identification of 2-hydroxyestrone-3-methyl ether in urine obtained from both pre- and postmenopausal women. This potentially protective estrogen metabolite has been previously reported only in the urine of pregnant women. Since individual patterns of estrogen metabolism may influence the risk of breast cancer, accurate and specific measurement of estrogen metabolites in biological matrixes will facilitate future research on breast cancer prevention, screening, and treatment.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15456304     DOI: 10.1021/ac049405i

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  4 in total

1.  Improved profiling of estrogen metabolites by orbitrap LC/MS.

Authors:  Xingnan Li; Adrian A Franke
Journal:  Steroids       Date:  2014-12-25       Impact factor: 2.668

2.  Analysis of steroidal estrogens as pyridine-3-sulfonyl derivatives by liquid chromatography electrospray tandem mass spectrometry.

Authors:  Li Xu; David C Spink
Journal:  Anal Biochem       Date:  2007-11-28       Impact factor: 3.365

3.  Stable isotope-coded quaternization for comparative quantification of estrogen metabolites by high-performance liquid chromatography-electrospray ionization mass spectrometry.

Authors:  Wen-Chu Yang; Fred E Regnier; Dan Sliva; Jiri Adamec
Journal:  J Chromatogr B Analyt Technol Biomed Life Sci       Date:  2008-06-20       Impact factor: 3.205

4.  An alternative method for the determination of estrogens in surface water and wastewater treatment plant effluent using pre-column trimethylsilyl derivatization and gas chromatography/mass spectrometry.

Authors:  Yiqi Zhou; Jun Zhou; Yiping Xu; Jinmiao Zha; Mei Ma; Zijian Wang
Journal:  Environ Monit Assess       Date:  2008-10-21       Impact factor: 2.513

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.