Literature DB >> 15452770

Comparative diagnostic performance of two commercial rapid tests for malaria in a non-endemic area.

F De Monbrison1, P Gérome, J F Chaulet, M Wallon, S Picot, F Peyron.   

Abstract

In the study reported here, the diagnostic performance of two new rapid tests for the diagnosis of malaria was evaluated in symptomatic patients in a non-endemic area. Of 557 consecutive patients, 109 (19.6%) had documented malaria. For the NOW ICT MALARIA P.f./P.v. (Binax, Portland, ME, USA) and OptiMAL IT (Diamed, Cressier, Switzerland) tests, respectively, sensitivity values were 96.3% and 79.8% (P-value, 0.0001), and specificity values were 98.8% and 98.4%. The NOW ICT test did not detect two of 80 Plasmodium falciparum infections, and it generated false-positive results for five patients. The OptiMAL IT test failed to detect ten of the P. falciparum infections, and it generated seven false-positive results. The results suggest that these rapid diagnostic tests for malaria may be useful, but they cannot replace microscopic examination of blood films.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15452770     DOI: 10.1007/s10096-004-1202-9

Source DB:  PubMed          Journal:  Eur J Clin Microbiol Infect Dis        ISSN: 0934-9723            Impact factor:   3.267


  13 in total

1.  Disappearance of pan-malarial antigen reactivity using the ICT Malaria P.f/P.v kit parallels decline of patent parasitaemia as shown by microscopy.

Authors:  D P Eisen; A Saul
Journal:  Trans R Soc Trop Med Hyg       Date:  2000 Mar-Apr       Impact factor: 2.184

2.  Performance of the OptiMAL malaria antigen capture dipstick for malaria diagnosis and treatment monitoring at the Hospital for Tropical Diseases, London.

Authors:  A Moody; A Hunt-Cooke; E Gabbett; P Chiodini
Journal:  Br J Haematol       Date:  2000-06       Impact factor: 6.998

3.  Non-microscopic method for malaria diagnosis using OptiMAL IT, a second-generation dipstick for malaria pLDH antigen detection.

Authors:  A H Moody; P L Chiodini
Journal:  Br J Biomed Sci       Date:  2002       Impact factor: 3.829

Review 4.  Rapid diagnostic tests for malaria parasites.

Authors:  Anthony Moody
Journal:  Clin Microbiol Rev       Date:  2002-01       Impact factor: 26.132

5.  Field evaluation of the ICT malaria P.f/P.v immunochromatographic test for detection of Plasmodium falciparum and Plasmodium vivax in patients with a presumptive clinical diagnosis of malaria in eastern Indonesia.

Authors:  E Tjitra; S Suprianto; M Dyer; B J Currie; N M Anstey
Journal:  J Clin Microbiol       Date:  1999-08       Impact factor: 5.948

6.  Evaluation of the OptiMAL test for rapid diagnosis of Plasmodium vivax and Plasmodium falciparum malaria.

Authors:  C J Palmer; J F Lindo; W I Klaskala; J A Quesada; R Kaminsky; M K Baum; A L Ager
Journal:  J Clin Microbiol       Date:  1998-01       Impact factor: 5.948

7.  Use of dipstick tests for the rapid diagnosis of malaria in nonimmune travelers.

Authors:  T Jelinek; M P Grobusch; H D Nothdurft
Journal:  J Travel Med       Date:  2000 Jul-Aug       Impact factor: 8.490

8.  Immunocapture diagnostic assays for malaria using Plasmodium lactate dehydrogenase (pLDH).

Authors:  R Piper; J Lebras; L Wentworth; A Hunt-Cooke; S Houzé; P Chiodini; M Makler
Journal:  Am J Trop Med Hyg       Date:  1999-01       Impact factor: 2.345

9.  Comparison of the ParaSight-F test and the ICT Malaria Pf test with the polymerase chain reaction for the diagnosis of Plasmodium falciparum malaria in travellers.

Authors:  P Pieroni; C D Mills; C Ohrt; M A Harrington; K C Kain
Journal:  Trans R Soc Trop Med Hyg       Date:  1998 Mar-Apr       Impact factor: 2.184

10.  Diagnosis of malaria by detection of Plasmodium falciparum HRP-2 antigen with a rapid dipstick antigen-capture assay.

Authors:  C Beadle; G W Long; W R Weiss; P D McElroy; S M Maret; A J Oloo; S L Hoffman
Journal:  Lancet       Date:  1994-03-05       Impact factor: 79.321

View more
  24 in total

1.  Performance of BinaxNOW for diagnosis of malaria in a U.S. hospital.

Authors:  Michael A Dimaio; Irma T Pereira; Tracy I George; Niaz Banaei
Journal:  J Clin Microbiol       Date:  2012-06-20       Impact factor: 5.948

2.  Differences in microscopic diagnosis of helminths and intestinal protozoa among diagnostic centres.

Authors:  I I Bogoch; G Raso; E K N'Goran; H P Marti; J Utzinger
Journal:  Eur J Clin Microbiol Infect Dis       Date:  2006-05       Impact factor: 3.267

3.  Malaria diagnosis by NOW ICT and expert microscopy in comparison with multiplex polymerase chain reaction in febrile returned travellers.

Authors:  J Cuadros; P Martín-Rabadán; F J Merino; A Delgado-Irribarren; S Garcia-Bujalance; J M Rubio
Journal:  Eur J Clin Microbiol Infect Dis       Date:  2007-09       Impact factor: 3.267

4.  Evaluation of the Immunoquick+4 malaria rapid diagnostic test in a non-endemic setting.

Authors:  D P J van Dijk; P Gillet; E Vlieghe; L Cnops; M Van Esbroeck; J Jacobs
Journal:  Eur J Clin Microbiol Infect Dis       Date:  2010-03-16       Impact factor: 3.267

Review 5.  Update on rapid diagnostic testing for malaria.

Authors:  Clinton K Murray; Robert A Gasser; Alan J Magill; R Scott Miller
Journal:  Clin Microbiol Rev       Date:  2008-01       Impact factor: 26.132

6.  Evaluation of a rapid diagnostic test (CareStart Malaria HRP-2/pLDH (Pf/pan) Combo Test) for the diagnosis of malaria in a reference setting.

Authors:  Jessica Maltha; Philippe Gillet; Emmanuel Bottieau; Lieselotte Cnops; Marjan van Esbroeck; Jan Jacobs
Journal:  Malar J       Date:  2010-06-18       Impact factor: 2.979

7.  Is serial testing required to diagnose imported malaria in the era of rapid diagnostic tests?

Authors:  Janet M Pasricha; Surender Juneja; Joseph Manitta; Susan Whitehead; Ellen Maxwell; Wai-Keong Goh; Sant-Rayn Pasricha; Damon P Eisen
Journal:  Am J Trop Med Hyg       Date:  2012-12-03       Impact factor: 2.345

8.  Use of the rapid BinaxNOW malaria test in a 24-hour laboratory associated with accurate detection and decreased malaria testing turnaround times in a pediatric setting where malaria is not endemic.

Authors:  K Ota-Sullivan; D L Blecker-Shelly
Journal:  J Clin Microbiol       Date:  2013-02-13       Impact factor: 5.948

9.  Test characteristics of the SD FK80 Plasmodium falciparum/Plasmodium vivax malaria rapid diagnostic test in a non-endemic setting.

Authors:  Philippe Gillet; David P J van Dijk; Emmanuel Bottieau; Lieselotte Cnops; Marjan Van Esbroeck; Jan Jacobs
Journal:  Malar J       Date:  2009-11-22       Impact factor: 2.979

10.  Comparison of different methods for delayed post-mortem diagnosis of falciparum malaria.

Authors:  Nicole Berens-Riha; Inga Sinicina; Erna Fleischmann; Thomas Löscher
Journal:  Malar J       Date:  2009-10-28       Impact factor: 2.979

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.