Literature DB >> 15449572

Technical considerations for fan-beam dual-energy x-ray absorptiometry body composition measurements in pediatric studies.

Mouhanad Hammami1, Winston W K Koo, Elaine M Hockman.   

Abstract

BACKGROUND: A piglet model was used to determine the influence of frequently encountered situations in clinical studies of infants and young children on fan-beam dual-energy x-ray absorptiometry (DXA) measurements.
METHODS: DXA scans of piglets (640 g to 21,100 g) were acquired in the infant and adult mode and were analyzed with 1 infant, 1 pediatric, and 3 versions of adult software.
RESULTS: The effect of repositioning of the piglets from the center to the periphery of the scanning table on DXA measurements included an average difference of up to 0.5% for total weight, 5.0% for bone mineral content, 5.6% for bone mineral density, 1.3% for lean mass, and 21.9% for fat mass (< or = .05, all comparisons) although no significant changes occurred when the piglets were scanned in symmetrical positions on either edge of the scanning table. Different posture (prone vs supine and side), varied number of blankets overlaid or wrapped around the piglet, and parenteral but not enteral bolus feeding could significantly alter fan-beam DXA measurements to varying extents. Adult and pediatric software underestimated bone area and bone mineral content but overestimated bone mineral density, lean mass, fat mass, and total weight compared with infant software measurements. However, strong predictive relationships among these fan-beam DXA data in subjects >10 kg allow systematic corrections of data from different scan modes and different software.
CONCLUSIONS: Attention to details and consistency in the technique for scan acquisition and analysis are critical to the generation of meaningful data and to allow for detection of true differences in DXA measurements of small subjects.

Entities:  

Mesh:

Year:  2004        PMID: 15449572     DOI: 10.1177/0148607104028005328

Source DB:  PubMed          Journal:  JPEN J Parenter Enteral Nutr        ISSN: 0148-6071            Impact factor:   4.016


  5 in total

1.  Reproducibility of DXA measurements of bone mineral density and body composition in children.

Authors:  Cheryl M Leonard; Melissa A Roza; Ronald D Barr; Colin E Webber
Journal:  Pediatr Radiol       Date:  2008-12-04

2.  Lack of Effect of Graded Doses of Vitamin D on Bone Metabolism of Breastfed Infants.

Authors:  Ekhard E Ziegler; Winston Wk Koo; Steven E Nelson; Janice M Jeter
Journal:  J Clin Nutr Metab       Date:  2017-09-27

3.  Lumbar spine and total-body dual-energy X-ray absorptiometry in children with severe neurological impairment and intellectual disability: a pilot study of artefacts and disrupting factors.

Authors:  S Mergler; R Rieken; D Tibboel; H M Evenhuis; R R van Rijn; C Penning
Journal:  Pediatr Radiol       Date:  2012-01-18

Review 4.  Pediatric DXA: technique and interpretation.

Authors:  Larry A Binkovitz; Maria J Henwood
Journal:  Pediatr Radiol       Date:  2006-05-20

5.  Developmental variations in plasma leptin, leptin soluble receptor and their molar ratio in healthy infants.

Authors:  Winston W K Koo; Mouhanad Hammami; Elaine M Hockman
Journal:  Nutr J       Date:  2007-06-04       Impact factor: 3.271

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.