Literature DB >> 15449210

Tissue ablation-rate measurements with a long-pulsed, fibre-deliverable 308 nm excimer laser.

Andrea K Murray1, Mark R Dickinson.   

Abstract

This ablation rate study has been carried out with a fibre-deliverable, 308 nm, XeCl laser, producing long pulses of 200 ns as opposed to the usual 10-20 ns. This in-depth study aimed to evaluate the ablation rates for this longer pulse length. The effects on the ablation depth of dentine, enamel, soft tissue and bone were investigated ex vivo. Radiant exposure, number of pulses, pulse repetition rate and spot size were independently varied. For all tissues, ablation depth per pulse was found to increase, initially, linearly with radiant exposure. For both dentine and soft tissue a saturation radiant exposure was determined; thereafter the ablation rate decreased. The depth per pulse increased linearly with repetition rate but decreased logarithmically with both number of pulses and spot size. The ablation depth due to a 200 ns pulse is comparable to that caused by a 10-20 ns pulse but has the advantage of fibre delivery.

Mesh:

Year:  2004        PMID: 15449210     DOI: 10.1007/s10103-004-0315-9

Source DB:  PubMed          Journal:  Lasers Med Sci        ISSN: 0268-8921            Impact factor:   3.161


  15 in total

1.  Er:YAG laser ablation of enamel and dentin of human teeth: determination of ablation rates at various fluences and pulse repetition rates.

Authors:  Z Z Li; J E Code; W P Van De Merwe
Journal:  Lasers Surg Med       Date:  1992       Impact factor: 4.025

2.  Effect of force on ablation depth for a XeCl excimer laser beam delivered by an optical fiber in contact with arterial tissue under saline.

Authors:  G H Gijsbers; D G van den Broecke; R L Sprangers; M J van Gemert
Journal:  Lasers Surg Med       Date:  1992       Impact factor: 4.025

3.  Role of tissue optics and pulse duration on tissue effects during high-power laser irradiation.

Authors:  S L Jacques
Journal:  Appl Opt       Date:  1993-05-01       Impact factor: 1.980

4.  Studies in fiber guided excimer laser surgery for cutting and drilling bone and meniscus.

Authors:  M Dressel; R Jahn; W Neu; K H Jungbluth
Journal:  Lasers Surg Med       Date:  1991       Impact factor: 4.025

5.  Etch rate and spectroscopic ablation studies of Er:YAG laser-irradiated dentine.

Authors:  S R Farrar; D C Attril; M R Dickinson; T A King; A S Blinkhorn
Journal:  Appl Opt       Date:  1997-08-01       Impact factor: 1.980

6.  The effect of CO2 laser pulse repetition rate on tissue ablation rate and thermal damage.

Authors:  V Venugopalan; N S Nishioka; B B Mikić
Journal:  IEEE Trans Biomed Eng       Date:  1991-10       Impact factor: 4.538

7.  Patients' perception of lasers in dentistry.

Authors:  H Wigdor
Journal:  Lasers Surg Med       Date:  1997       Impact factor: 4.025

8.  Effects of Er:YAG laser in caries treatment: a clinical pilot study.

Authors:  U Keller; R Hibst
Journal:  Lasers Surg Med       Date:  1997       Impact factor: 4.025

9.  Use of the Er:YAG laser for improved plating in maxillofacial surgery: comparison of bone healing in laser and drill osteotomies.

Authors:  K U Lewandrowski; C Lorente; K T Schomacker; T J Flotte; J W Wilkes; T F Deutsch
Journal:  Lasers Surg Med       Date:  1996       Impact factor: 4.025

Review 10.  Lasers in dentistry.

Authors:  H A Wigdor; J T Walsh; J D Featherstone; S R Visuri; D Fried; J L Waldvogel
Journal:  Lasers Surg Med       Date:  1995       Impact factor: 4.025

View more
  1 in total

1.  Advances in bone surgery: the Er:YAG laser in oral surgery and implant dentistry.

Authors:  Stefan Stübinger
Journal:  Clin Cosmet Investig Dent       Date:  2010-06-30
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.