Literature DB >> 15446503

Noninvasive measurement of steady and pulsating velocity profiles and shear rates in arteries using echo PIV: in vitro validation studies.

Hyoung-Bum Kim1, Jean Hertzberg, Craig Lanning, Robin Shandas.   

Abstract

Although accurate measurement of velocity profiles, multiple velocity vectors, and shear stress in arteries is important, there is still no easy method to obtain such information in vivo. We report on the utility of combining ultrasound contrast imaging with particle image velocimetry (PIV) for noninvasive measurement of velocity vectors. This method (echo PIV) takes advantage of the strong backscatter characteristics of small gas-filled microbubbles (contrast) seeded into the flow. The method was tested in vitro. The steady flow analytical solution and optical PIV measurements (for pulsatile flow) were used for comparison. When compared to the analytical solution, both echo PIV and optical PIV resolved the steady velocity profile well. Error in shear rate as measured by echo PIV (8%) was comparable to the error of optical PIV (6.5%). In pulsatile flow, echo PIV velocity profiles agreed well with optical PIV profiles. Echo PIV followed the general profile of pulsatile shear stress across the artery but underestimated wall shear at certain time points. However, error in shear from echo PIV was an order of magnitude less than error from current shear measurement methods. These studies indicate that echo PIV is a promising technique for noninvasive measurement of velocity profiles and shear stress.

Entities:  

Mesh:

Year:  2004        PMID: 15446503     DOI: 10.1114/b:abme.0000036643.45452.6d

Source DB:  PubMed          Journal:  Ann Biomed Eng        ISSN: 0090-6964            Impact factor:   3.934


  14 in total

1.  Velocity field measurements of valvular blood flow in a human superficial vein using high-frequency ultrasound speckle image velocimetry.

Authors:  Kweon-Ho Nam; Eunseop Yeom; Hojin Ha; Sang-Joon Lee
Journal:  Int J Cardiovasc Imaging       Date:  2010-12-28       Impact factor: 2.357

2.  Modeling and phantom studies of ultrasonic wall shear rate measurements using coded pulse excitation.

Authors:  Jean K Tsou; Jie Liu; Michael F Insana
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2006-04       Impact factor: 2.725

Review 3.  New echocardiographic techniques for evaluation of left atrial mechanics.

Authors:  Maria Chiara Todaro; Indrajit Choudhuri; Marek Belohlavek; Arshad Jahangir; Scipione Carerj; Lilia Oreto; Bijoy K Khandheria
Journal:  Eur Heart J Cardiovasc Imaging       Date:  2012-08-21       Impact factor: 6.875

4.  Real-time texture analysis for identifying optimum microbubble concentration in 2-D ultrasonic particle image velocimetry.

Authors:  Lili Niu; Ming Qian; Liang Yan; Wentao Yu; Bo Jiang; Qiaofeng Jin; Yanping Wang; Robin Shandas; Xin Liu; Hairong Zheng
Journal:  Ultrasound Med Biol       Date:  2011-06-17       Impact factor: 2.998

5.  In vitro and preliminary in vivo validation of echo particle image velocimetry in carotid vascular imaging.

Authors:  Fuxing Zhang; Craig Lanning; Luciano Mazzaro; Alex J Barker; Phillip E Gates; W David Strain; Jonathan Fulford; Oliver E Gosling; Angela C Shore; Nick G Bellenger; Bryan Rech; Jiusheng Chen; James Chen; Robin Shandas
Journal:  Ultrasound Med Biol       Date:  2011-03       Impact factor: 2.998

6.  Measurement of Wall Shear Stress Exerted by Flowing Blood in the Human Carotid Artery: Ultrasound Doppler Velocimetry and Echo Particle Image Velocimetry.

Authors:  Phillip E Gates; Arati Gurung; Luciano Mazzaro; Kuni Aizawa; Salim Elyas; William D Strain; Angela C Shore; Robin Shandas
Journal:  Ultrasound Med Biol       Date:  2018-04-17       Impact factor: 2.998

7.  Impact of pulmonary vascular stiffness and vasodilator treatment in pediatric pulmonary hypertension: 21 patient-specific fluid-structure interaction studies.

Authors:  Zhenbi Su; Kendall S Hunter; Robin Shandas
Journal:  Comput Methods Programs Biomed       Date:  2011-10-04       Impact factor: 5.428

8.  Impact of acute moderate elevation in left ventricular afterload on diastolic transmitral flow efficiency: analysis by vortex formation time.

Authors:  Panupong Jiamsripong; Anna M Calleja; Mohsen S Alharthi; Mate Dzsinich; Eileen M McMahon; Jeffrey J Heys; Michele Milano; Partho P Sengupta; Bijoy K Khandheria; Marek Belohlavek
Journal:  J Am Soc Echocardiogr       Date:  2009-01-25       Impact factor: 5.251

9.  Ultrasound imaging velocimetry with interleaved images for improved pulsatile arterial flow measurements: a new correction method, experimental and in vivo validation.

Authors:  Katharine H Fraser; Christian Poelma; Bin Zhou; Eleni Bazigou; Meng-Xing Tang; Peter D Weinberg
Journal:  J R Soc Interface       Date:  2017-02       Impact factor: 4.118

Review 10.  Left ventricular flow analysis: recent advances in numerical methods and applications in cardiac ultrasound.

Authors:  Iman Borazjani; John Westerdale; Eileen M McMahon; Prathish K Rajaraman; Jeffrey J Heys; Marek Belohlavek
Journal:  Comput Math Methods Med       Date:  2013-04-17       Impact factor: 2.238

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.