Literature DB >> 1543691

Effect of pressure on aortic hydraulic conductance.

A L Baldwin1, L M Wilson, B R Simon.   

Abstract

This study was performed to determine whether the transmural hydraulic conductance (Lp) of the rabbit aortic wall depends on its distension. In 19 rabbits, the aorta was cannulated in situ and perfused at a given pressure with a physiologically buffered solution containing 4% bovine serum albumin. The output cannula was then occluded to limit fluid flow to that traversing the artery wall. External diameter and transmural fluid flow were measured at three pressures (eight rabbits, group 1) or at four pressures (12 rabbits, group 2) in each vessel. Transmural fluid flow was determined by monitoring the velocity of an air bubble within a buffer-filled tube leading to the input cannula. From group 1 measurements, Lp values (mean +/- SD) at 50, 100, and 150 mm Hg were calculated to be 3.8 +/- 2.8, 3.5 +/- 1.3, and 4.1 +/- 1.2 x 10(-8) cm/sec/mm Hg, respectively. Group 2 measurements gave values of 4.2 +/- 1.6, 3.8 +/- 1.1, 3.8 +/- 1.1, and 4.2 +/- 1.1 x 10(-8) cm/sec/mm Hg at 75, 100, 125, and 150 mm Hg, respectively. Paired Student's t tests indicated no significant change in Lp with pressure. However, linear regression analysis demonstrated a weak correlation between Lp values obtained at 50 and 100 mm Hg (r2 = 0.30) and at 75 and 100 mm Hg (r2 = 0.36). Values of Lp at 100 and 150 mm Hg and at 125 and 150 mm Hg were closely correlated in each case. These results suggest that between 50 and 100 mm Hg the structural properties of the aortic wall change so as to alter Lp but not in the same way in each vessel. Lp may increase or decrease depending on which structural change predominates in a particular vessel.

Entities:  

Mesh:

Year:  1992        PMID: 1543691     DOI: 10.1161/01.atv.12.2.163

Source DB:  PubMed          Journal:  Arterioscler Thromb        ISSN: 1049-8834


  9 in total

1.  Alternative blood conduits: assessment of whether the porosity of synthetic prostheses is the key to long-term biofunctionality.

Authors:  X Deng; R Guidoin
Journal:  Med Biol Eng Comput       Date:  2000-03       Impact factor: 2.602

2.  Effect of pressure on transmural fluid flow in different de-endothelialised arteries.

Authors:  P Dhar; G Jayaraman; N Karmakar; S C Manchanda
Journal:  Med Biol Eng Comput       Date:  1996-03       Impact factor: 2.602

3.  Chronic hypertension increases aortic endothelial hydraulic conductivity by upregulating endothelial aquaporin-1 expression.

Authors:  Jimmy Toussaint; Chirag Bharavi Raval; Tieuvi Nguyen; Hadi Fadaifard; Shripad Joshi; George Wolberg; Steven Quarfordt; Kung-Ming Jan; David S Rumschitzki
Journal:  Am J Physiol Heart Circ Physiol       Date:  2017-07-21       Impact factor: 4.733

4.  Numerical simulation of haemodynamics and low-density lipoprotein transport in the rabbit aorta and their correlation with atherosclerotic plaque thickness.

Authors:  Xiaoyin Li; Xiao Liu; Peng Zhang; Chenglong Feng; Anqiang Sun; Hongyan Kang; Xiaoyan Deng; Yubo Fan
Journal:  J R Soc Interface       Date:  2017-04       Impact factor: 4.118

5.  Aquaporin-1 facilitates pressure-driven water flow across the aortic endothelium.

Authors:  Tieuvi Nguyen; Jimmy Toussaint; Yan Xue; Chirag Raval; Limary Cancel; Stewart Russell; Yixin Shou; Omer Sedes; Yu Sun; Roman Yakobov; John M Tarbell; Kung-ming Jan; David S Rumschitzki
Journal:  Am J Physiol Heart Circ Physiol       Date:  2015-02-06       Impact factor: 4.733

6.  A multiphasic model for determination of water and solute transport across the arterial wall: effects of elastic fiber defects.

Authors:  Young Guang; Austin J Cocciolone; Christie L Crandall; Benjamin B Johnston; Lori A Setton; Jessica E Wagenseil
Journal:  Arch Appl Mech       Date:  2021-06-03       Impact factor: 1.976

7.  Endothelial barrier dysfunction in diabetic conduit arteries: a novel method to quantify filtration.

Authors:  Xiao Lu; Virginia H Huxley; Ghassan S Kassab
Journal:  Am J Physiol Heart Circ Physiol       Date:  2012-12-07       Impact factor: 4.733

8.  Intimal and medial contributions to the hydraulic resistance of the arterial wall at different pressures: a combined computational and experimental study.

Authors:  K Y Chooi; A Comerford; S J Sherwin; P D Weinberg
Journal:  J R Soc Interface       Date:  2016-06       Impact factor: 4.118

9.  Direct visualization of interstitial flow distribution in aortic walls.

Authors:  Wataru Fukui; Yoshihiro Ujihara; Masanori Nakamura; Shukei Sugita
Journal:  Sci Rep       Date:  2022-03-30       Impact factor: 4.379

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.