Literature DB >> 1540563

Perfluorocarbon heavy liquids in the management of posterior dislocation of the lens nucleus during phakoemulsification.

N J Rowson1, A S Bacon, P H Rosen.   

Abstract

We report a case in which the lens nucleus dislocated into the vitreous cavity through a posterior capsular rupture during phakoemulsification. We performed a vitrectomy and removed the lens nucleus using the perfluorocarbon heavy liquid perfluoro-1,3-dimethylcyclohexane. The management of posterior dislocation of the lens nucleus during cataract surgery is discussed.

Entities:  

Mesh:

Substances:

Year:  1992        PMID: 1540563      PMCID: PMC504198          DOI: 10.1136/bjo.76.3.169

Source DB:  PubMed          Journal:  Br J Ophthalmol        ISSN: 0007-1161            Impact factor:   4.638


  5 in total

1.  Experimental evaluation of perfluorophenanthrene as a high specific gravity vitreous substitute: a preliminary report.

Authors:  M Nabih; G A Peyman; L C Clark; R E Hoffman; M Miceli; M Abou-Steit; M Tawakol; K R Liu
Journal:  Ophthalmic Surg       Date:  1989-04

2.  Experimental vitreous replacement with perfluorotributylamine.

Authors:  S Chang; N J Zimmerman; T Iwamoto; R Ortiz; D Faris
Journal:  Am J Ophthalmol       Date:  1987-01-15       Impact factor: 5.258

3.  Low viscosity liquid fluorochemicals in vitreous surgery.

Authors:  S Chang
Journal:  Am J Ophthalmol       Date:  1987-01-15       Impact factor: 5.258

4.  Perfluoroether liquid as a long-term vitreous substitute. An experimental study.

Authors:  K Miyamoto; M F Refojo; F I Tolentino; G A Fournier; D M Albert
Journal:  Retina       Date:  1984 Fall-Winter       Impact factor: 4.256

5.  Perfluorocarbon liquids in the management of traumatic retinal detachments.

Authors:  S Chang; V Reppucci; N J Zimmerman; M H Heinemann; D J Coleman
Journal:  Ophthalmology       Date:  1989-06       Impact factor: 12.079

  5 in total
  5 in total

1.  Phacoemulsification with perfluorocarbon liquid using a 23-gauge transconjunctival sutureless vitrectomy for the management of dislocated crystalline lenses.

Authors:  Hyun Duk Jang; Soo Jung Lee; Jung Min Park
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2012-10-07       Impact factor: 3.117

2.  Comparision of surgical outcomes of intraocular lens refixation and intraocular lens exchange with perfluorocarbon liquid and fibrin glue-assisted sutureless scleral fixation.

Authors:  S Y Oh; S J Lee; J M Park
Journal:  Eye (Lond)       Date:  2015-03-20       Impact factor: 3.775

3.  Use of perfluorocarbon liquid during vitrectomy for severe proliferative diabetic retinopathy.

Authors:  Y Imamura; M Minami; M Ueki; B Satoh; T Ikeda
Journal:  Br J Ophthalmol       Date:  2003-05       Impact factor: 4.638

4.  The effect of specific gravity of perfluorocarbon liquid on the retina after experimental vitreous substitution.

Authors:  Ulrike Stolba; Katharina Krepler; Michaela Velikay-Parel; Susanne Binder
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2004-07-17       Impact factor: 3.117

Review 5.  [Heavy liquids as intraoperative instrument in retinal surgery].

Authors:  Karl Boden; K Januschowski; P Szurman
Journal:  Ophthalmologe       Date:  2019-10       Impact factor: 1.059

  5 in total