Literature DB >> 1540439

A model to simulate the haemodynamic effects of right heart pulsatile flow after modified Fontan procedure.

S Tamaki1, K Kawazoe, T Yagihara, T Abe.   

Abstract

The effect of pulsatile pulmonary flow after the modified Fontan procedure was examined in a model that simulated the right heart. An inlet overflow tank (preload), axial pulsatile pump, Wind-Kessel model (afterload), and an outlet overflow tank were connected in series. The standard conditions were flow 2.00 l/min with 12 mm Hg preload pressure, 3.0 Wood units resistance, and an outlet overflow tank pressure at 6 mm Hg. The pump rate was set at 80 beats/min. The simulated pulmonary arterial pressure and pulmonary flow waves produced by this model closely resembled those obtained from patients who had undergone the modified Fontan procedure. All variables except the preload were fixed and changes in pulmonary flow were examined at preload pressures of 8, 12, 15, and 17 mm Hg. As the peak pulmonary arterial pressure increased so did pulmonary flow, until it was greater than during the non-pulsatile state. Because the afterload of this model was fixed, this result suggests that there was a concomitant decrease in resistance. This model indicates that pulsatile pulmonary blood flow is likely to have a beneficial effect on the pulmonary circulation after the modified Fontan procedure.

Entities:  

Mesh:

Year:  1992        PMID: 1540439      PMCID: PMC1024750          DOI: 10.1136/hrt.67.2.177

Source DB:  PubMed          Journal:  Br Heart J        ISSN: 0007-0769


  9 in total

1.  Evaluation of right atrial-pulmonary artery conduits for tricuspid atresia. Experimental study.

Authors:  R J Shemin; W H Merrill; J S Pfeifer; D M Conkle; A G Morrow
Journal:  J Thorac Cardiovasc Surg       Date:  1979-05       Impact factor: 5.209

2.  Instantaneous pressure-volume relationship of right atrium during isovolumic contraction in canine heart.

Authors:  V K Lau; K Sagawa; H Suga
Journal:  Am J Physiol       Date:  1979-05

3.  Surgical correction of tricuspid atresia.

Authors:  D N Ross; J Somerville
Journal:  Lancet       Date:  1973-04-21       Impact factor: 79.321

4.  Dynamics of right heart flow in patients after Fontan procedure.

Authors:  M Nakazawa; T Nakanishi; H Okuda; G Satomi; S Nakae; Y Imai; A Takao
Journal:  Circulation       Date:  1984-02       Impact factor: 29.690

5.  Clinical and hemodynamic results of the Fontan operation for tricuspid atresia.

Authors:  S P Sanders; G B Wright; J F Keane; W I Norwood; A R Castaneda
Journal:  Am J Cardiol       Date:  1982-05       Impact factor: 2.778

6.  Total cavopulmonary connection: a logical alternative to atriopulmonary connection for complex Fontan operations. Experimental studies and early clinical experience.

Authors:  M R de Leval; P Kilner; M Gewillig; C Bull
Journal:  J Thorac Cardiovasc Surg       Date:  1988-11       Impact factor: 5.209

7.  Cardiovascular status after repair by Fontan procedure.

Authors:  D M Behrendt; A Rosenthal
Journal:  Ann Thorac Surg       Date:  1980-04       Impact factor: 4.330

8.  Experimental evaluation of atrial function in right atrium--pulmonary artery conduit operation for tricuspid atresia.

Authors:  H Matsuda; Y Kawashima; H Takano; K Miyamoto; T Mori
Journal:  J Thorac Cardiovasc Surg       Date:  1981-05       Impact factor: 5.209

9.  Postoperative evaluation of the Fontan procedure by radionuclide angiography.

Authors:  G G Janos; M J Gelfand; D C Schwartz; S Kaplan
Journal:  Am Heart J       Date:  1982-10       Impact factor: 4.749

  9 in total
  5 in total

1.  Instantaneous pressure-flow velocity relations of systemic venous return in patients with univentricular circulation.

Authors:  R Kaulitz; P Bergman; I Luhmer; T Paul; G Hausdorf
Journal:  Heart       Date:  1999-09       Impact factor: 5.994

2.  Development of a thermodynamic control system for the Fontan circulation pulsation device using shape memory alloy fibers.

Authors:  Akihiro Yamada; Yasuyuki Shiraishi; Hidekazu Miura; Hashem Mohamed Omran Hashem; Yusuke Tsuboko; Masaaki Yamagishi; Tomoyuki Yambe
Journal:  J Artif Organs       Date:  2015-04-18       Impact factor: 1.731

3.  A model to simulate the effects of right heart pulsatile flow after modified Fontain procedure.

Authors:  P Kilner; M de Leval
Journal:  Br Heart J       Date:  1993-01

Review 4.  Modeling the Fontan circulation: where we are and where we need to go.

Authors:  C G DeGroff
Journal:  Pediatr Cardiol       Date:  2007-10-05       Impact factor: 1.655

5.  Echocardiographic Assessment of Pulmonary Arteries Pulsatility Index in Fontan Circulation.

Authors:  Reza Shabanian; Mohammad Reza Mirzaaghayan; Minoo Dadkhah; Mehdi Hosseini; Mitra Rahimzadeh; Parvin Akbari Asbagh; Mohammad Ali Navabi
Journal:  J Cardiovasc Ultrasound       Date:  2015-12-30
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.