On flow effects in balanced steady-state free precession imaging: pictorial description, parameter dependence, and clinical implications.

Michael Markl1, Norbert J Pelc.   

Abstract

PURPOSE: To present a pictorial description of the origin of flow effects in balanced steady-state free precession (SSFP) imaging that can result in considerable frequency offset-dependent signal changes originating from outflow of spins that can still contribute to the total SSFP signal (out-of-slice contributions), to analyze the parameter dependence and slice broadening associated with outflow effects, and to illustrate clinical implications such as frequency offset-dependent flow artifacts and spatial misencoding.
MATERIALS AND METHODS: Computer simulations were used to create a pictorial description of flow effects that illustrates the origin and parameter dependence of the observed signal changes and links their frequency dependency to the phase distribution of spins flowing in and out of the imaging slice. Slice broadening associated with out-of-slice contributions and flow-related signal enhancement was characterized by an effective slice thickness, which depends on flow rate, the T2* decay of signal magnitude from spins that have left the imaging slice, and the ratio of the net out-of-slice magnetization relative to the thickness of the imaging slice.
RESULTS: Both simulated SSFP signal intensities and effective slice broadening vary with flip angle and demonstrate a nonlinear dependence on inflow. Simulations with bloodlike T1 and T2 show that the effective slice thickness can be as large as 15 times the prescribed slice thickness. These effects can have significant clinical implications such as large frequency offset-dependent signal enhancement, pulsatile flow artifacts, and spatial misrepresentation of blood signal that has already left the imaging slice.
CONCLUSION: Flow-related signal changes in SSFP imaging exhibit highly complex parameter dependence, which predominantly has to be associated with frequency offset-dependent outflow effects and a resulting broadening of the slice thickness. Copyright 2004 Wiley-Liss, Inc.

Mesh:

Year:  2004        PMID: 15390233     DOI: 10.1002/jmri.20163

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  17 in total

1.  Banding-free balanced SSFP cardiac cine using frequency modulation and phase cycle redundancy.

Authors:  Anjali Datta; Dwight G Nishimura; Corey A Baron
Journal:  Magn Reson Med       Date:  2019-06-22       Impact factor: 4.668

2.  Ungated radial quiescent-inflow single-shot (UnQISS) magnetic resonance angiography using optimized azimuthal equidistant projections.

Authors:  Robert R Edelman; Shivraman Giri; Ian G Murphy; Oisin Flanagan; Peter Speier; Ioannis Koktzoglou
Journal:  Magn Reson Med       Date:  2014-09-24       Impact factor: 4.668

3.  Dynamic magnetic resonance imaging of endoscopic third ventriculostomy patency with differently acquired fast imaging with steady-state precession sequences.

Authors:  Milos A Lucic; Katarina Koprivsek; Dusko Kozic; Martina Spero; Milena Spirovski; Silvija Lucic
Journal:  Bosn J Basic Med Sci       Date:  2014-08-16       Impact factor: 3.363

4.  Mitigation of near-band balanced steady-state free precession through-plane flow artifacts using partial dephasing.

Authors:  Anjali Datta; Joseph Y Cheng; Brian A Hargreaves; Corey A Baron; Dwight G Nishimura
Journal:  Magn Reson Med       Date:  2017-10-10       Impact factor: 4.668

Review 5.  Magnetic resonance imaging for characterizing myocardial diseases.

Authors:  Maythem Saeed; Hui Liu; Chang-Hong Liang; Mark W Wilson
Journal:  Int J Cardiovasc Imaging       Date:  2017-03-31       Impact factor: 2.357

6.  Fat-water separation in dynamic objects using an UNFOLD-like temporal processing.

Authors:  Riad Ababneh; Jing Yuan; Bruno Madore
Journal:  J Magn Reson Imaging       Date:  2010-10       Impact factor: 4.813

7.  Radial fast interrupted steady-state (FISS) magnetic resonance imaging.

Authors:  Ioannis Koktzoglou; Robert R Edelman
Journal:  Magn Reson Med       Date:  2017-08-30       Impact factor: 4.668

8.  Halting the effects of flow enhancement with effective intermittent zeugmatographic encoding (HEFEWEIZEN) in SSFP.

Authors:  Jamal J Derakhshan; Mark A Griswold; Jeffrey L Sunshine; Jeffrey L Duerk
Journal:  J Magn Reson Imaging       Date:  2009-05       Impact factor: 4.813

9.  Free-breathing variable flip angle balanced SSFP cardiac cine imaging with reduced SAR at 3T.

Authors:  Subashini Srinivasan; Randall M Kroeker; Simon Gabriel; Adam Plotnik; Sergio R Godinez; Peng Hu; Nancy Halnon; J Paul Finn; Daniel B Ennis
Journal:  Magn Reson Med       Date:  2015-10-28       Impact factor: 4.668

Review 10.  Cardiovascular magnetic resonance artefacts.

Authors:  Pedro F Ferreira; Peter D Gatehouse; Raad H Mohiaddin; David N Firmin
Journal:  J Cardiovasc Magn Reson       Date:  2013-05-22       Impact factor: 5.364

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.