Literature DB >> 15389507

Evaluation of wear resistance of dental resin composites with a 3D profilometer.

Hyun-Suk Cha1, Yong-Keun Lee, Bum-Soon Lim, Sang-Hoon Rhee, Hyeong-Cheol Yang.   

Abstract

The objectives of this study were to determine the wear resistance of dental resin composites, and to evaluate the influence of wear-simulating apparatus on wear. Nine commercial resin composites were studied. Wear was simulated with an oral wear simulator (Proto-Tech), which simultaneously incorporates the wear mechanism of attrition and abrasion in three-body wear mode, and with a pin-on-disk type friction tester (Rhesca, Japan). Composite specimens were subjected to 50,000 cycles of wear against a dental porcelain antagonist. After wear simulation, parameters for the determination of wear amount, such as wear volume, maximum wear depth, mean of maximum wear depth, and average wear depth were measured with the use of a 3D profilometer. For the oral wear simulator, the range of wear volume was 4.3-9.2 x 10(-2) mm3, and there were significant differences among the composites (p < 0.05). In other parameters, there were no significant differences among the composites. For the pin-on-disk tester, the range of mean of maximum wear depth was 7.5-26.3 microm, which was significantly different among the composites (p < 0.05). Correlation coefficient (r) between the wear volume from the oral wear simulator and the mean of maximum wear depth from the pin-on-disk tester was 0.52. Conclusively, dental resin composites showed significantly different wear resistance. Wear simulating apparatus influenced the amount of wear, and suitable parameters for the determination of wear amounts should be selected in each apparatus. (c) 2004 Wiley Periodicals, Inc.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15389507     DOI: 10.1002/jbm.b.30108

Source DB:  PubMed          Journal:  J Biomed Mater Res B Appl Biomater        ISSN: 1552-4973            Impact factor:   3.368


  3 in total

1.  Are resin composites suitable replacements for amalgam? A study of two-body wear.

Authors:  Dimitra Lazaridou; Renan Belli; Anselm Petschelt; Ulrich Lohbauer
Journal:  Clin Oral Investig       Date:  2014-12-10       Impact factor: 3.573

2.  Influence of orthodontic adhesives and clean-up procedures on the stain susceptibility of enamel after debonding.

Authors:  Hyun-Jin Joo; Yong-Keun Lee; Dong-Yul Lee; Yae-Jin Kim; Yong-Kyu Lim
Journal:  Angle Orthod       Date:  2011-03       Impact factor: 2.079

3.  In Vitro Investigation of Wear of CAD/CAM Polymeric Materials Against Primary Teeth.

Authors:  Jae-Won Choi; Eun-Ju Song; Jong-Hyun Shin; Tae-Sung Jeong; Jung-Bo Huh
Journal:  Materials (Basel)       Date:  2017-12-09       Impact factor: 3.623

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.