A Sanches-Silva1, A Rodríguez-Bernaldo de Quirós, J López-Hernández, P Paseiro-Losada.
Abstract
Hexanal (an oxidative state indicator) formed in the headspace of potato crisps during storage was evaluated using two different procedures. First, solid-phase microextraction, an innovative sampling preparation methodology was used. It consisted on the absorption of analytes directly from samples and subsequent thermal desorption on the gas chromatograph (GC) injector. Then, a reversed-phase high-performance liquid chromatographic technique (HPLC) was employed to quantify hexanal in the form of 2,4-dinitrophenylhydrazone derivative. Methods were evaluated in what concerns to validation parameters such as linearity, repeatibility and detection limit. GC (LOD = 1 ng/ml) method resulted in more sensitive method than HPLC (LOD = 9 ng/ml). The most suitable technique for hexanal measurement was selected.Entities:
Mesh:
Substances:
Year: 2004 PMID: 15387173 DOI: 10.1016/j.chroma.2004.06.101
Source DB: PubMed Journal: J Chromatogr A ISSN: 0021-9673 Impact factor: 4.759