Literature DB >> 15385841

Determination of cyclosporine in saliva using liquid chromatography-tandem mass spectrometry.

Anisha Mendonza1, Reginald Gohh, Fatemeh Akhlaghi.   

Abstract

Saliva may offer an alternative specimen for the therapeutic monitoring of cyclosporine (CsA) in children and patients with difficult venous access. For a highly protein-bound drug such as CsA, saliva may also provide a practical approach for measuring the unbound concentration. Liquid chromatography-tandem mass spectrometry (LC-MS/MS) is ideally suited for the measurement of drugs in saliva. A solid-phase extraction technique, analytic liquid chromatography over an Aqua Perfect C18 column, maintained at 65 degrees C, and electrospray tandem mass spectrometry were used to quantify CsA in saliva. The method used cyclosporine C (CsC) as the internal standard. Mobile phase comprised of a 97:3 vol/vol mixture of methanol and 30 mmol ammonium acetate at a flow rate of 0.5 mL/min. Chromatograms using mass transitions of m/z 1219.9 --> m/z 1202.9 for CsA and m/z 1235.9 --> m/z 1218.9 for CsC were obtained. The calibration curve was linear from 1 to 300 microg/L with correlation coefficient values ranging from 0.9732 to 0.9968). The lower limit of quantification was 1 microg/L, and limit of detection was 0.6 microg/L with an average extraction recovery of 84.7 +/- 2.6% for CsA and 93.7 +/- 4.4% for CsC from the saliva matrix. The accuracy of the method ranged from 92% to 104.7%, and the intra- and interrun coefficients of variation were 6.9-12.2% and 8.3-12.1%, respectively. The correlation coefficient value between the CsA concentration measurements in 15 paired blood-saliva samples from kidney transplant recipients was 0.695 (P = 0.006). The noninvasive and simple method of saliva collection coupled with the LC-MS/MS quantification technique for CsA analysis would generate novel data that could benefit patients undergoing CsA therapy.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15385841     DOI: 10.1097/00007691-200410000-00016

Source DB:  PubMed          Journal:  Ther Drug Monit        ISSN: 0163-4356            Impact factor:   3.681


  7 in total

1.  Measurement of saliva tacrolimus levels in pediatric renal transplant recipients.

Authors:  Vladimir Belostotsky; Jo Adaway; Brian G Keevil; Dena R Cohen; Nicholas J A Webb
Journal:  Pediatr Nephrol       Date:  2010-10-24       Impact factor: 3.714

Review 2.  Alternative matrices for therapeutic drug monitoring of immunosuppressive agents using LC-MS/MS.

Authors:  Mwlod Ghareeb; Fatemeh Akhlaghi
Journal:  Bioanalysis       Date:  2015       Impact factor: 2.681

3.  Development and Validation of a RP-HPLC Method for Determination of Cyclosporine in Capsule.

Authors:  F Aziz; A Gupta; M F Khan
Journal:  Indian J Pharm Sci       Date:  2010-03       Impact factor: 0.975

4.  Tacrolimus Concentration in Saliva of Kidney Transplant Recipients: Factors Influencing the Relationship with Whole Blood Concentrations.

Authors:  Mwlod Ghareeb; Reginald Y Gohh; Fatemeh Akhlaghi
Journal:  Clin Pharmacokinet       Date:  2018-09       Impact factor: 6.447

5.  Could Salivary Cyclosporine Dosage Replace the Whole Blood Cyclosporine Measurements in Renal Transplant Patients?

Authors:  Samia Aboujaoude; Marwan Masri; Sylvana Rizk; Souleima Chamat; Jad Farha; Zeina Majzoub
Journal:  J Int Soc Prev Community Dent       Date:  2017-05-22

Review 6.  Saliva as a Future Field in Psoriasis Research.

Authors:  Farah Asa'ad; Marco Fiore; Aniello Alfieri; Paolo Daniele Maria Pigatto; Chiara Franchi; Emilio Berti; Carlo Maiorana; Giovanni Damiani
Journal:  Biomed Res Int       Date:  2018-05-20       Impact factor: 3.411

7.  Saliva as Blood Alternative in Therapeutic Monitoring of Teriflunomide-Development and Validation of the Novel Analytical Method.

Authors:  Bartłomiej Sankowski; Sylwia Michorowska; Emilia Raćkowska; Mariusz Sikora; Joanna Giebułtowicz
Journal:  Int J Mol Sci       Date:  2022-08-23       Impact factor: 6.208

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.