Literature DB >> 15383972

[Tissue harmonic imaging (THI) and contrast harmonic imaging (CHI) for sonographically guided vacuum-assisted biopsy of mammographically occult breast tumors].

E M Jung1, K-P Jungius, M Lenhart, M Dengler, H Becker, N Rupp.   

Abstract

PURPOSE: To assess the guidance of tissue harmonic imaging (THI) and contrast harmonic imaging (CHI) for vacuum assisted biopsies of suspicious breast lesions compared to fundamental B-mode ultrasound-guided biopsies.
MATERIAL AND METHODS: In 550 patients, ultrasound examinations of the breast were performed prospectively using fundamental B-scan, THI, and CHI. Focal lesions were documented in comparable projections for all three ultrasound modes. As contrast agent, a dose of 0.5 milliliters of Perflutren Protein-Type A microspheres ( Optison) was injected. An ultrasound-guided biopsy was performed in 38 focal lesions. Three radiologists experienced in breast imaging retrospectively assessed the lesions on the ultrasound images.
RESULTS: Thirty-eight suspicious focal lesions [size 4 - 15 mm; median 8 mm] were detected by ultrasound. Of these, 29 were detected by fundamental B-scan images, 34 by THI, and 38 by CHI. Ultrasound-guided biopsy was performed on all of these lesions. No complications related to the biopsy were observed. In 25/38 cases, invasive carcinomas were found; in 6/38 ductal carcinomas in situ; in 3 cases metastases of already known invasive ductal carcinomas; and in 4 cases fibroadenomas. The size of the lesion was best identified using THI, smaller lesions (< 10 mm) using CHI.
CONCLUSION: THI and CHI can help to detect focal lesions in dense breasts. Both modes can make it easier to perform ultrasound-guided biopsies of focal breast lesions.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15383972     DOI: 10.1055/s-2004-813534

Source DB:  PubMed          Journal:  Rofo        ISSN: 1438-9010


  2 in total

Review 1.  Accuracy of ultrasound-guided, large-core needle breast biopsy.

Authors:  G Schueller; C Schueller-Weidekamm; T H Helbich
Journal:  Eur Radiol       Date:  2008-04-15       Impact factor: 5.315

2.  Value of tissue harmonic imaging (THI) and contrast harmonic imaging (CHI) in detection and characterisation of breast tumours.

Authors:  D- A Clevert; E M Jung; K-P Jungius; K Ertan; R Kubale
Journal:  Eur Radiol       Date:  2006-07-06       Impact factor: 5.315

  2 in total