Literature DB >> 15382829

A physiologically representative in vitro model of the coronary circulation.

Maartje C F Geven1, Vincent N Bohté, Wilbert H Aarnoudse, Petra M J van den Berg, Marcel C M Rutten, Nico H J Pijls, Frans N van de Vosse.   

Abstract

With the development of clinical diagnostic techniques to investigate the coronary circulation in conscious humans, the in vitro validation of such newly developed techniques is of major importance. The aim of this study was to develop an in vitro model that is able to mimic the coronary circulation in such a way that coronary pressure and flow signals under baseline as well as hyperaemic conditions are approximated as realistically as possible and are in accordance with recently gained insights into such signals in conscious man. In the present in vitro model the heart, the systemic and coronary circulation are modelled on the basis of the elements of a lumped parameter mathematical model only consisting of elements that can be represented by segments in an experimental set-up. A collapsible tube, collapsed by the ventricular pressure, represents the variable resistance and volume behaviour of the endocardial part of the myocardium. The pressure and flow signals obtained are similar to physiological human coronary pressure and flow, both for baseline and hyperaemic conditions. The model allows for in vitro evaluation of clinical diagnostic techniques.

Entities:  

Mesh:

Year:  2004        PMID: 15382829     DOI: 10.1088/0967-3334/25/4/009

Source DB:  PubMed          Journal:  Physiol Meas        ISSN: 0967-3334            Impact factor:   2.833


  8 in total

Review 1.  The arterial Windkessel.

Authors:  Nico Westerhof; Jan-Willem Lankhaar; Berend E Westerhof
Journal:  Med Biol Eng Comput       Date:  2008-06-10       Impact factor: 2.602

2.  Development of an In Vitro Model to Characterize the Effects of Transcatheter Aortic Valve on Coronary Artery Flow.

Authors:  Joseph Calderan; Wenbin Mao; Eric Sirois; Wei Sun
Journal:  Artif Organs       Date:  2015-10-29       Impact factor: 3.094

3.  Numerical Parametric Study of Paravalvular Leak Following a Transcatheter Aortic Valve Deployment Into a Patient-Specific Aortic Root.

Authors:  Wenbin Mao; Qian Wang; Susheel Kodali; Wei Sun
Journal:  J Biomech Eng       Date:  2018-10-01       Impact factor: 2.097

Review 4.  Review of zero-D and 1-D models of blood flow in the cardiovascular system.

Authors:  Yubing Shi; Patricia Lawford; Rodney Hose
Journal:  Biomed Eng Online       Date:  2011-04-26       Impact factor: 2.819

5.  Effects of Pulsatile Frequency of Left Ventricular Assist Device (LVAD) on Coronary Perfusion: A Numerical Simulation Study.

Authors:  Yuanfei Zhu; Ming Yang; Yan Zhang; Fan Meng; Tianyue Yang; Zhiwei Fang
Journal:  Med Sci Monit       Date:  2020-09-17

6.  Effect of Collateral Flow on Catheter-Based Assessment of Cardiac Microvascular Obstruction.

Authors:  Mirunalini Thirugnanasambandam; Sabrina Frey; Yannick Rösch; Alberto Mantegazza; Francesco Clavica; Robert S Schwartz; Nikola Cesarovic; Dominik Obrist
Journal:  Ann Biomed Eng       Date:  2022-05-31       Impact factor: 4.219

7.  Effects of Choice of Medical Imaging Modalities on a Non-invasive Diagnostic and Monitoring Computational Framework for Patients With Complex Valvular, Vascular, and Ventricular Diseases Who Undergo Transcatheter Aortic Valve Replacement.

Authors:  Melissa Baiocchi; Shirley Barsoum; Seyedvahid Khodaei; Jose M de la Torre Hernandez; Sydney E Valentino; Emily C Dunford; Maureen J MacDonald; Zahra Keshavarz-Motamed
Journal:  Front Bioeng Biotechnol       Date:  2021-07-08

8.  A mathematical model of coronary blood flow control: simulation of patient-specific three-dimensional hemodynamics during exercise.

Authors:  Christopher J Arthurs; Kevin D Lau; Kaleab N Asrress; Simon R Redwood; C Alberto Figueroa
Journal:  Am J Physiol Heart Circ Physiol       Date:  2016-03-04       Impact factor: 4.733

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.