Literature DB >> 1538257

In vitro validation of a thermodilution right ventricular ejection fraction method.

S E Ferris1, M Konno.   

Abstract

A thermodilution catheter and computer system has been developed to measure right ventricular ejection fraction and volumes. To evaluate the performance of this method, the thermodilution system was evaluated in an in vitro pulsatile flow model. Thermodilution measurements of ejection fraction (EF), cardiac output (CO), stroke volume (SV), end-diastolic volume (EDV), and end-systolic volume (ESV) were compared with known values in a pulsatile flow bench. Thermodilution EF measurements correlated very well with the pulsatile flow model (r2 = 0.95, m [slope] = 0.85, SEE = 4.0 EFU). Thermodilution CO and SV were highly predictive of actual pulsatile flow (r2 = 0.99, m = 0.99, SEE = 187 ml/min and r2 = 0.98, m = 0.96, SEE = 2.5 ml, respectively). Thermodilution end-diastolic and end-systolic volume measurements resulted in low mean eror, -1.8% and 0.6%, respectively. The standard deviations of the error for EDV and ESV were 11.0% and 16.4%. The thermodilution measurements were repeatable, with CO, SV, and EF coefficients of variation of 3.2%, 3.3%, and 4.7%, respectively. EDV and ESV were slightly more variable, with coefficients of variation of 5.5% and 7.2%, respectively.

Entities:  

Mesh:

Year:  1992        PMID: 1538257     DOI: 10.1007/bf01618092

Source DB:  PubMed          Journal:  J Clin Monit        ISSN: 0748-1977


  13 in total

1.  Thermodilution right ventricular ejection fraction. Catheter positioning effects.

Authors:  F G Spinale; J L Zellner; R Mukherjee; S E Ferris; F A Crawford
Journal:  Chest       Date:  1990-11       Impact factor: 9.410

2.  Revascularization of the right coronary artery: influence on thermodilution right ventricular ejection fraction.

Authors:  J Boldt; D Kling; A Thiel; H H Scheld; G Hempelmann
Journal:  J Cardiothorac Anesth       Date:  1988-04

3.  Bedside evaluation of right ventricular performance using a rapid computerized thermodilution method.

Authors:  J F Dhainaut; F Brunet; J F Monsallier; D Villemant; J Y Devaux; M Konno; J M De Gournay; A Armaganidis; G Iotti; M F Huyghebaert
Journal:  Crit Care Med       Date:  1987-02       Impact factor: 7.598

4.  Thermodilution measurement of right ventricular ejection fraction with a modified pulmonary artery catheter.

Authors:  J L Vincent; M Thirion; S Brimioulle; P Lejeune; R J Kahn
Journal:  Intensive Care Med       Date:  1986       Impact factor: 17.440

5.  Hybrid computer for dye-dilution curves.

Authors:  I K Daskalov; L V Gueorguiev; M G Matveev
Journal:  Med Biol Eng Comput       Date:  1978-01       Impact factor: 2.602

6.  Thermodilution cardiac output determination with a single flow-directed catheter.

Authors:  J S Forrester; W Ganz; G Diamond; T McHugh; D W Chonette; H J Swan
Journal:  Am Heart J       Date:  1972-03       Impact factor: 4.749

Review 7.  Measurement of blood flow by thermodilution.

Authors:  W Ganz; H J Swan
Journal:  Am J Cardiol       Date:  1972-02       Impact factor: 2.778

Review 8.  The right ventricle and critical illness: a review of anatomy, physiology, and clinical evaluation of its function.

Authors:  W E Hurford; W M Zapol
Journal:  Intensive Care Med       Date:  1988       Impact factor: 17.440

9.  Right ventricular function computed by thermodilution and ventriculography. A comparison of methods.

Authors:  F G Spinale; A C Smith; B A Carabello; F A Crawford
Journal:  J Thorac Cardiovasc Surg       Date:  1990-01       Impact factor: 5.209

10.  Determination of right ventricular ejection fraction by thermodilution technique--a comparison to biplane cineventriculography.

Authors:  W Voelker; H P Gruber; O Ickrath; R Unterberg; K R Karsch
Journal:  Intensive Care Med       Date:  1988       Impact factor: 17.440

View more
  3 in total

Review 1.  [Haemodynamic effects of mechanical ventilation].

Authors:  T Luecke; P Pelosi; M Quintel
Journal:  Anaesthesist       Date:  2007-12       Impact factor: 1.041

Review 2.  Clinical review: Positive end-expiratory pressure and cardiac output.

Authors:  Thomas Luecke; Paolo Pelosi
Journal:  Crit Care       Date:  2005-10-18       Impact factor: 9.097

Review 3.  The contemporary pulmonary artery catheter. Part 2: measurements, limitations, and clinical applications.

Authors:  I T Bootsma; E C Boerma; T W L Scheeren; F de Lange
Journal:  J Clin Monit Comput       Date:  2021-03-01       Impact factor: 2.502

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.