Literature DB >> 15379021

Physiological noise in murine solid tumours using T2*-weighted gradient-echo imaging: a marker of tumour acute hypoxia?

Christine Baudelet1, Réginald Ansiaux, Bénédicte F Jordan, Xavier Havaux, Benoit Macq, Bernard Gallez.   

Abstract

T2*-weighted gradient-echo magnetic resonance imaging (T2*-weighted GRE MRI) was used to investigate spontaneous fluctuations in tumour vasculature non-invasively. FSa fibrosarcomas, implanted intramuscularly (i.m.) in the legs of mice, were imaged at 4.7 T, over a 30 min or 1 h sampling period. On a voxel-by-voxel basis, time courses of signal intensity were analysed using a power spectrum density (PSD) analysis to isolate voxels for which signal changes did not originate from Gaussian white noise or linear drift. Under baseline conditions, the tumours exhibited spontaneous signal fluctuations showing spatial and temporal heterogeneity over the tumour. Statistically significant fluctuations occurred at frequencies ranging from 1 cycle/3 min to 1 cycle/h. The fluctuations were independent of the scanner instabilities. Two categories of signal fluctuations were reported: (i) true fluctuations (TFV), i.e., sequential signal increase and decrease, and (ii) profound drop in signal intensity with no apparent signal recovery (SDV). No temporal correlation between tumour and contralateral muscle fluctuations was observed. Furthermore, treatments aimed at decreasing perfusion-limited hypoxia, such as carbogen combined with nicotinamide and flunarizine, decreased the incidence of tumour T2*-weighted GRE fluctuations. We also tracked dynamic changes in T2* using multiple GRE imaging. Fluctuations of T2* were observed; however, fluctuation maps using PSD analysis could not be generated reliably. An echo-time dependency of the signal fluctuations was observed, which is typical to physiological noise. Finally, at the end of T2*-weighted GRE MRI acquisition, a dynamic contrast-enhanced MRI was performed to characterize the microenvironment in which tumour signal fluctuations occurred in terms of vessel functionality, vascularity and microvascular permeability. Our data showed that TFV were predominantly located in regions with functional vessels, whereas SDV occurred in regions with no contrast enhancement as the result of vessel functional impairment. Furthermore, transient fluctuations appeared to occur preferentially in neoangiogenic hyperpermeable vessels. The present study suggests that spontaneous T2*-weighted GRE fluctuations are very likely to be related to the spontaneous fluctuations in blood flow and oxygenation associated with the pathophysiology of acute hypoxia in tumours. The disadvantage of the T2*-weighted GRE MRI technique is the complexity of signal interpretation with regard to pO2 changes. Compared to established techniques such as intravital microscopy or histological assessments, the major advantage of the MRI technique lies in its capacity to provide simultaneously both temporal and detailed spatial information on spontaneous fluctuations throughout the tumour.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15379021     DOI: 10.1088/0031-9155/49/15/006

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  36 in total

1.  Low-field magnetic resonance imaging to visualize chronic and cycling hypoxia in tumor-bearing mice.

Authors:  Hironobu Yasui; Shingo Matsumoto; Nallathamby Devasahayam; Jeeva P Munasinghe; Rajani Choudhuri; Keita Saito; Sankaran Subramanian; James B Mitchell; Murali C Krishna
Journal:  Cancer Res       Date:  2010-07-20       Impact factor: 12.701

2.  Sensitivity analysis of an image-based solid tumor computational model with heterogeneous vasculature and porosity.

Authors:  Gregory L Pishko; Garrett W Astary; Thomas H Mareci; Malisa Sarntinoranont
Journal:  Ann Biomed Eng       Date:  2011-07-13       Impact factor: 3.934

3.  Mapping in vivo tumor oxygenation within viable tumor by 19F-MRI and multispectral analysis.

Authors:  Yunzhou Shi; Jason Oeh; Jeffrey Eastham-Anderson; Sharon Yee; David Finkle; Franklin V Peale; Jed Ross; Maj Hedehus; Nicholas van Bruggen; Rayna Venook; Sarajane Ross; Deepak Sampath; Richard A D Carano
Journal:  Neoplasia       Date:  2013-11       Impact factor: 5.715

Review 4.  Imaging tumour hypoxia with oxygen-enhanced MRI and BOLD MRI.

Authors:  James P B O'Connor; Simon P Robinson; John C Waterton
Journal:  Br J Radiol       Date:  2019-01-24       Impact factor: 3.039

5.  Fabrication and physical evaluation of a polymer-encapsulated paramagnetic probe for biomedical oximetry.

Authors:  Guruguhan Meenakshisundaram; Edward Eteshola; Ramasamy P Pandian; Anna Bratasz; Stephen C Lee; Periannan Kuppusamy
Journal:  Biomed Microdevices       Date:  2009-08       Impact factor: 2.838

6.  Interstitial diffuse optical probe with spectral fitting to measure dynamic tumor hypoxia.

Authors:  Leonard Che Fru; Steven L Jacques; Kwang P Nickel; Tomy Varghese; Michael W Kissick; Larry A DeWerd; Randall J Kimple
Journal:  Biomed Phys Eng Express       Date:  2020-01-31

7.  High resolution ultra high field magnetic resonance imaging of glioma microvascularity and hypoxia using ultra-small particles of iron oxide.

Authors:  Gregory A Christoforidis; Ming Yang; Marinos S Kontzialis; Douglas G Larson; Amir Abduljalil; Michelle Basso; Weilian Yang; Abhik Ray-Chaudhury; Johannes Heverhagen; Michael V Knopp; Rolf F Barth
Journal:  Invest Radiol       Date:  2009-07       Impact factor: 6.016

8.  Potential role of the glycolytic oscillator in acute hypoxia in tumors.

Authors:  Leonard Che Fru; Erin B Adamson; David D Campos; Sean B Fain; Steven L Jacques; Albert J van der Kogel; Kwang P Nickel; Chihwa Song; Randall J Kimple; Michael W Kissick
Journal:  Phys Med Biol       Date:  2015-11-18       Impact factor: 3.609

9.  Regulation of the Warburg effect in early-passage breast cancer cells.

Authors:  Ian F Robey; Renu M Stephen; Kathy S Brown; Brenda K Baggett; Robert A Gatenby; Robert J Gillies
Journal:  Neoplasia       Date:  2008-08       Impact factor: 5.715

10.  PET hypoxia imaging with FAZA: reproducibility at baseline and during fractionated radiotherapy in tumour-bearing mice.

Authors:  M Busk; L S Mortensen; M Nordsmark; J Overgaard; S Jakobsen; K V Hansen; J Theil; J F Kallehauge; F P D'Andrea; T Steiniche; M R Horsman
Journal:  Eur J Nucl Med Mol Imaging       Date:  2012-10-18       Impact factor: 9.236

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.