Literature DB >> 15378700

A simple and inexpensive approach to interfacing high-performance liquid chromatography and matrix-assisted laser desorption/ionization-time of flight-mass spectrometry.

Kim Y C Fung1, Srdjan Askovic, Franco Basile, Mark W Duncan.   

Abstract

The ability to obtain the accurate mass of a protein in a complex sample mixture aids in determining its correct in vivo form. This is important when identifying post-translationally modified proteins, protein variants or isoforms. The central technique used to separate proteins, 2-dimensional gel electrophoresis offers excellent separation capabilities but does not provide adequate mass accuracy. In this study, an alternative method, liquid chromatography (LC) coupled with matrix-assisted laser desorption/ionization-time of flight (MALDI-TOF)-MS (LC-MALDI) is described. LC-MALDI-MS was used to separate and determine the mass of proteins and peptides in a complex biological sample (i.e., human pituitary gland homogenate). Peptides and proteins were first separated by capillary chromatography and the eluent mixed post-column with sinapinic acid matrix. The flow was then deposited directly onto a standard MALDI target via a capillary nebulizer. In addition to offering high mass accuracy, this method can be applied to peptide and protein quantification.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15378700     DOI: 10.1002/pmic.200300843

Source DB:  PubMed          Journal:  Proteomics        ISSN: 1615-9853            Impact factor:   3.984


  6 in total

1.  Clustering of pentacene and functionalized pentacene ions in a matrix-assisted laser desorption/ionization orthogonal TOF mass spectrometer.

Authors:  Svitlana V Shcherbyna; Diethard K Bohme; Vladimir I Baranov; Alexander Loboda; Christopher R Swartz; John E Anthony
Journal:  J Am Soc Mass Spectrom       Date:  2006-01-18       Impact factor: 3.109

2.  An impulse-driven liquid-droplet deposition interface for combining LC with MALDI MS and MS/MS.

Authors:  J Bryce Young; Liang Li
Journal:  J Am Soc Mass Spectrom       Date:  2006-01-27       Impact factor: 3.109

3.  Desorption electrospray ionization-mass spectrometry of proteins.

Authors:  Yong-Seung Shin; Barbara Drolet; Richard Mayer; Kurt Dolence; Franco Basile
Journal:  Anal Chem       Date:  2007-03-30       Impact factor: 6.986

4.  Imaging MALDI mass spectrometry of sphingolipids using an oscillating capillary nebulizer matrix application system.

Authors:  Yanfeng Chen; Ying Liu; Jeremy Allegood; Elaine Wang; Begoña Cachón-González; Timothy M Cox; Alfred H Merrill; M Cameron Sullards
Journal:  Methods Mol Biol       Date:  2010

5.  Enhanced protein identification using graphite-modified MALDI plates for offline LC-MALDI-MS/MS bottom-up proteomics.

Authors:  Anthony Maus; Rudolph Mignon; Franco Basile
Journal:  Anal Biochem       Date:  2018-01-08       Impact factor: 3.365

6.  Methodology and applications of disease biomarker identification in human serum.

Authors:  Ziad J Sahab; Suzan M Semaan; Qing-Xiang Amy Sang
Journal:  Biomark Insights       Date:  2007-02-14
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.