Literature DB >> 15377114

Accurate estimation of the Fisher information matrix for the PET image reconstruction problem.

Quanzheng Li1, Evren Asma, Jinyi Qi, James R Bading, Richard M Leahy.   

Abstract

The Fisher information matrix (FIM) plays a key role in the analysis and applications of statistical image reconstruction methods based on Poisson data models. The elements of the FIM are a function of the reciprocal of the mean values of sinogram elements. Conventional plug-in FIM estimation methods do not work well at low counts, where the FIM estimate is highly sensitive to the reciprocal mean estimates at individual detector pairs. A generalized error look-up table (GELT) method is developed to estimate the reciprocal of the mean of the sinogram data. This approach is also extended to randoms precorrected data. Based on these techniques, an accurate FIM estimate is obtained for both Poisson and randoms precorrected data. As an application, the new GELT method is used to improve resolution uniformity and achieve near-uniform image resolution in low count situations.

Mesh:

Year:  2004        PMID: 15377114     DOI: 10.1109/TMI.2004.833202

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  8 in total

1.  Digimouse: a 3D whole body mouse atlas from CT and cryosection data.

Authors:  Belma Dogdas; David Stout; Arion F Chatziioannou; Richard M Leahy
Journal:  Phys Med Biol       Date:  2007-01-10       Impact factor: 3.609

2.  Regularization parameter selection for penalized-likelihood list-mode image reconstruction in PET.

Authors:  Mengxi Zhang; Jian Zhou; Xiaofeng Niu; Evren Asma; Wenli Wang; Jinyi Qi
Journal:  Phys Med Biol       Date:  2017-04-12       Impact factor: 3.609

3.  Quantitative Accuracy of Penalized-Likelihood Reconstruction for ROI Activity Estimation.

Authors:  Lin Fu; Jennifer R Stickel; Ramsey D Badawi; Jinyi Qi
Journal:  IEEE Trans Nucl Sci       Date:  2009-02-01       Impact factor: 1.679

4.  Iterative PET Image Reconstruction Using Translation Invariant Wavelet Transform.

Authors:  Jian Zhou; Lotfi Senhadji; Jean-Louis Coatrieux; Limin Luo
Journal:  IEEE Trans Nucl Sci       Date:  2009-02       Impact factor: 1.679

5.  Regularization design in penalized maximum-likelihood image reconstruction for lesion detection in 3D PET.

Authors:  Li Yang; Jian Zhou; Andrea Ferrero; Ramsey D Badawi; Jinyi Qi
Journal:  Phys Med Biol       Date:  2013-12-19       Impact factor: 3.609

6.  Quadratic regularization design for 2-D CT.

Authors:  Hugo R Shi; Jeffrey A Fessler
Journal:  IEEE Trans Med Imaging       Date:  2008-10-31       Impact factor: 10.048

Review 7.  Magnetic resonance-guided positron emission tomography image reconstruction.

Authors:  Bing Bai; Quanzheng Li; Richard M Leahy
Journal:  Semin Nucl Med       Date:  2013-01       Impact factor: 4.446

Review 8.  Quantitative statistical methods for image quality assessment.

Authors:  Joyita Dutta; Sangtae Ahn; Quanzheng Li
Journal:  Theranostics       Date:  2013-10-04       Impact factor: 11.556

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.