A novel test method for evaluation of the abrasive wear behaviour of total hip stems at the interface between implant surface and bone cement.

R Bader1, E Steinhauser, U Holzwarth, M Schmitt, W Mittelmeier.   

Abstract

After total hip replacement, some cemented titanium stems show above-average early loosening rates. Increased release of wear particles and resulting reaction of the peri-prosthetic tissue were considered responsible. The objective was to develop a test method for analysing the abrasive wear behaviour of cemented stems and for generating wear particles at the interface with the bone cement. By means of the novel test device, cemented hip stems with different designs, surface topographies and material compositions using various bone cements could be investigated. Before testing, the cemented stems were disconnected from the cement mantle to simulate the situation of stem loosening (debonding). Subsequently, constant radial contact pressures were applied on to the stem surface by a force-controlled hydraulic cylinder. Oscillating micromotions of the stem (+/- 250 microm; 3 x 10(6)cycles; 5 Hz) were carried out at the cement interface initiating the wear process. The usability of the method was demonstrated by testing geometrically identical Ti-6A1-7Nb and Co-28Cr-6Mo hip stems (n= 12) with definite rough and smooth surfaces, combined with commercially available bone cement containing zirconium oxide particles. Under identical frictional conditions with the rough shot-blasted stems, clearly more wear particles were generated than with the smooth stems, whereas the material composition of the hip stems had less impact on the wear behaviour.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15376724     DOI: 10.1243/0954411041561009

Source DB:  PubMed          Journal:  Proc Inst Mech Eng H        ISSN: 0954-4119            Impact factor:   1.617


  2 in total

1.  Contribution of human osteoblasts and macrophages to bone matrix degradation and proinflammatory cytokine release after exposure to abrasive endoprosthetic wear particles.

Authors:  Anika Jonitz-Heincke; Katrin Lochner; Christoph Schulze; Diana Pohle; Wera Pustlauk; Doris Hansmann; Rainer Bader
Journal:  Mol Med Rep       Date:  2016-06-21       Impact factor: 2.952

2.  Factors Influencing the Interactions in Gelatin/Hydroxyapatite Hybrid Materials.

Authors:  Zixin Zhang; Kexin Li; Weixian Zhou; Jin'ge Gu; Ying Liu; Charles C Han; Shanshan Xu
Journal:  Front Chem       Date:  2020-06-11       Impact factor: 5.221

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.